A verification study on the accuracy of virtual thoracic endovascular aneurysm repair procedure

Computational models in the cardiovascular field, among which in Thoracic Endovascular Aneurysm Repair (TEVAR)-which involves the deployment of a stent-graft to exclude pathological region of the aorta from circulation-are gaining interest among clinicians as tools to support pre-operative decision-making. To assess the credibility of in-silico models, the American Society of Mechanical Engineers published the V&V40 framework, which includes verification, validation, and uncertainty quantification. This study presents a verification analysis of TEVAR simulations to evaluate the impact of selected parameters on simulation outcomes, focusing on specific quantities of interests. Simulations were conducted on three patient-specific anatomies replicating the crimping, tracking, and release phases of the clinical procedure. Evaluated numerical parameters included mass damping, friction coefficient, tracking velocity, and release time. Sliding distance, rotation and computational time were analyzed in the tracking phase; while Opening Area, center-to-center distance, and plane rotation were evaluated in the release phase, comparing simulation results with post-operative CT segmentations. A mass damping coefficient of 0.1 ms<sup>-1</sup> for the stent-graft and 1 ms<sup>-1</sup> for the catheter, a friction coefficient of 1 between stent-graft and catheter, and a velocity of 0.5 m/s yielded the best results during tracking. In the release phase, the selected parameters were: a damping of 0.1 ms<sup>-1</sup>, a friction coefficient of 0.1, and a release time of 5 ms. In conclusion, this study provides a comprehensive analysis to support the selection of best settings for TEVAR simulations. A verification analysis is essential to understand the influence of numerical parameters on simulation outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-07-20
DOI
https://doi.org/10.1016/j.jbiomech.2025.112875
Citations
3
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
4.56
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A verification study on the accuracy of virtual thoracic endovascular aneurysm repair procedure

Francesco Migliavacca, Sara Barati, Anna Ramella, Santi Trimarchi et al.
3 citations
Journal of Biomechanics
Aortic aneurysm repair treatments
4.56
article

A verification study on the accuracy of virtual thoracic endovascular aneurysm repair procedure

Francesco Migliavacca, Sara Barati, Anna Ramella, Santi Trimarchi, Robin H. Heijmen, Giulia Luraghi, G. Campo
article en
3 citations

Abstract

Computational models in the cardiovascular field, among which in Thoracic Endovascular Aneurysm Repair (TEVAR)-which involves the deployment of a stent-graft to exclude pathological region of the aorta from circulation-are gaining interest among clinicians as tools to support pre-operative decision-making. To assess the credibility of in-silico models, the American Society of Mechanical Engineers published the V&V40 framework, which includes verification, validation, and uncertainty quantification. This study presents a verification analysis of TEVAR simulations to evaluate the impact of selected parameters on simulation outcomes, focusing on specific quantities of interests. Simulations were conducted on three patient-specific anatomies replicating the crimping, tracking, and release phases of the clinical procedure. Evaluated numerical parameters included mass damping, friction coefficient, tracking velocity, and release time. Sliding distance, rotation and computational time were analyzed in the tracking phase; while Opening Area, center-to-center distance, and plane rotation were evaluated in the release phase, comparing simulation results with post-operative CT segmentations. A mass damping coefficient of 0.1 ms<sup>-1</sup> for the stent-graft and 1 ms<sup>-1</sup> for the catheter, a friction coefficient of 1 between stent-graft and catheter, and a velocity of 0.5 m/s yielded the best results during tracking. In the release phase, the selected parameters were: a damping of 0.1 ms<sup>-1</sup>, a friction coefficient of 0.1, and a release time of 5 ms. In conclusion, this study provides a comprehensive analysis to support the selection of best settings for TEVAR simulations. A verification analysis is essential to understand the influence of numerical parameters on simulation outcomes.

Journal of BiomechanicsVol. 190
Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Politecnico di Milano (IT)
Good health and well-being
Openalex Percentile: Top 5%
Aortic aneurysm repair treatments
4.56
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.