Improvement in residual paravalvular leakage after transcatheter aortic valve replacement with a self-expanding valve: ACURATE neo2 versus ACURATE neo

The paravalvular leakage (PVL) incidence immediately after transcatheter aortic valve replacement (TAVR) is reportedly lower with ACURATE neo2 than with ACURATE neo. However, the difference in the subsequent PVL improvement between these valves and the improvement mechanism remain unclear. This study aimed to compare the incidence of and changes in the PVL between these valves and investigate the factors associated with PVL improvement. We included 403 patients who underwent TAVR with ACURATE neo2 (n = 134) or ACURATE neo (n = 269). The study endpoint was PVL improvement, defined as a reduction in the PVL grade from mild or higher at discharge to none/trace at 3 months. The PVL incidence of mild grade or higher was significantly lower with ACURATE neo2 than with ACURATE neo at 3 months (15.7% vs. 25.7%; p = 0.0234) but did not differ significantly at discharge (33.3% vs. 27.5%; p = 0.2291). A significant decrease in the PVL was observed only with ACURATE neo2 (p < 0.0001). Multivariate analysis demonstrated that ACURATE neo2 and calcium volume of the aortic leaflets were independent predictors of PVL improvement. The incidence of mild grade or higher PVL was lower with ACURATE neo2 than with ACURATE neo at 3 months due to the subsequent improvement. Patient selection focusing on leaflet calcification is important for preventing PVL because severe calcification impedes PVL improvement.

Authors

Institutions

Publication Details

Journal
Cardiovascular Intervention and Therapeutics
Published
2025-07-20
DOI
https://doi.org/10.1007/s12928-025-01170-1
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement in residual paravalvular leakage after transcatheter aortic valve replacement with a self-expanding valve: ACURATE neo2 versus ACURATE neo

Mikko Jalanko, Mika Laine, Hirokazu Miyashita, Juho Viikilä et al.
1 citations
Cardiovascular Intervention and Therapeutics
Cardiac Valve Diseases and Treatments
1.39
article

Improvement in residual paravalvular leakage after transcatheter aortic valve replacement with a self-expanding valve: ACURATE neo2 versus ACURATE neo

Mikko Jalanko, Mika Laine, Hirokazu Miyashita, Juho Viikilä, Noriaki Moriyama, Tiina Vainikka, Sebastian Dahlbacka, Tommi Vähäsilta, Yoichi Sugiyama
article en
1 citations

Abstract

The paravalvular leakage (PVL) incidence immediately after transcatheter aortic valve replacement (TAVR) is reportedly lower with ACURATE neo2 than with ACURATE neo. However, the difference in the subsequent PVL improvement between these valves and the improvement mechanism remain unclear. This study aimed to compare the incidence of and changes in the PVL between these valves and investigate the factors associated with PVL improvement. We included 403 patients who underwent TAVR with ACURATE neo2 (n = 134) or ACURATE neo (n = 269). The study endpoint was PVL improvement, defined as a reduction in the PVL grade from mild or higher at discharge to none/trace at 3 months. The PVL incidence of mild grade or higher was significantly lower with ACURATE neo2 than with ACURATE neo at 3 months (15.7% vs. 25.7%; p = 0.0234) but did not differ significantly at discharge (33.3% vs. 27.5%; p = 0.2291). A significant decrease in the PVL was observed only with ACURATE neo2 (p < 0.0001). Multivariate analysis demonstrated that ACURATE neo2 and calcium volume of the aortic leaflets were independent predictors of PVL improvement. The incidence of mild grade or higher PVL was lower with ACURATE neo2 than with ACURATE neo at 3 months due to the subsequent improvement. Patient selection focusing on leaflet calcification is important for preventing PVL because severe calcification impedes PVL improvement.

Cardiovascular Intervention and TherapeuticsVol. 40(4)
Helsinki University Hospital (FI), Shonan Kamakura General Hospital (JP)
Clean water and sanitation
Openalex Percentile: Top 17%
Cardiac Valve Diseases and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.