Reducing methane emissions from gravity sewer pipelines by ultrasonication

Methane (CH 4 ), a potent greenhouse gas (GHG), is a major concern in sewer pipelines, and its emissions can increase with food waste (FW) introduction via disposer systems. To mitigate these emissions, several chemical approaches have been attempted, yet they face environmental and economic challenges. In this study, ultrasonication was applied inside sewer pipelines at different intervals (30 min once every 4, 5, and 6 weeks) to evaluate its long-term effect on CH 4 emission reduction. Two lab-scale gravity sewer pipelines (7 m long, 80 mm diameter) were constructed and fed with: only domestic wastewater (R1) and domestic wastewater plus FW (R2). FW addition increased CH 4 emissions from 52 to 110 mL CH 4 /L sewage , due to higher organics entering the sewer pipelines (500→1,000 mg COD/L). Following ultrasonication, CH 4 emissions decreased by 40–56% and 34–39% in R1 and R2, respectively, attributed to biofilm detachment, as confirmed by changes in extracellular polymeric substances concentration and shear stress test. The average daily GHG reduction by ultrasonication was 10.5, 9.2, and 7.7 g CO 2 eq./d for R1, and 15.8, 14.6, and 13.9 g CO 2 eq./d for R2, at 4-, 5-, and 6-week intervals, respectively, clearly indicating a revival in CH 4 emissions. Considering the energy use, net GHG reduction effectiveness significantly dropped with longer intervals in R1 (38→28%), while remaining relatively stable (28–30%) in R2. These results emphasize the importance of shortening ultrasonication intervals, particularly when only domestic wastewater is conveyed in the sewer pipelines. • Significant amount of CH 4 emissions from sewer pipelines by biological reaction. • Introduction of food waste to the sewer pipelines doubled the CH 4 emissions. • Application of ultrasonication inside sewer pipelines to reduce the CH 4 emissions. • Ultrasonication reduced CH 4 emissions by 34-56% through biofilm detachment. • Increased ultrasonication intervals led to less CH 4 reduction, suggesting revival.

Authors

Institutions

Publication Details

Journal
Environmental Technology & Innovation
Published
2025-07-20
DOI
https://doi.org/10.1016/j.eti.2025.104391
Citations
2
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
1.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing methane emissions from gravity sewer pipelines by ultrasonication

Jong-Han Lee, Gyeongcheol Kim, Om Prakash, Dong-Hoon Kim et al.
2 citations
Environmental Technology & Innovation
Water Systems and Optimization
1.91
article

Reducing methane emissions from gravity sewer pipelines by ultrasonication

Jong-Han Lee, Gyeongcheol Kim, Om Prakash, Dong-Hoon Kim, Hojung Rho, Masoud Makian, Mohamadali Mohit
article en
2 citations

Abstract

Methane (CH 4 ), a potent greenhouse gas (GHG), is a major concern in sewer pipelines, and its emissions can increase with food waste (FW) introduction via disposer systems. To mitigate these emissions, several chemical approaches have been attempted, yet they face environmental and economic challenges. In this study, ultrasonication was applied inside sewer pipelines at different intervals (30 min once every 4, 5, and 6 weeks) to evaluate its long-term effect on CH 4 emission reduction. Two lab-scale gravity sewer pipelines (7 m long, 80 mm diameter) were constructed and fed with: only domestic wastewater (R1) and domestic wastewater plus FW (R2). FW addition increased CH 4 emissions from 52 to 110 mL CH 4 /L sewage , due to higher organics entering the sewer pipelines (500→1,000 mg COD/L). Following ultrasonication, CH 4 emissions decreased by 40–56% and 34–39% in R1 and R2, respectively, attributed to biofilm detachment, as confirmed by changes in extracellular polymeric substances concentration and shear stress test. The average daily GHG reduction by ultrasonication was 10.5, 9.2, and 7.7 g CO 2 eq./d for R1, and 15.8, 14.6, and 13.9 g CO 2 eq./d for R2, at 4-, 5-, and 6-week intervals, respectively, clearly indicating a revival in CH 4 emissions. Considering the energy use, net GHG reduction effectiveness significantly dropped with longer intervals in R1 (38→28%), while remaining relatively stable (28–30%) in R2. These results emphasize the importance of shortening ultrasonication intervals, particularly when only domestic wastewater is conveyed in the sewer pipelines. • Significant amount of CH 4 emissions from sewer pipelines by biological reaction. • Introduction of food waste to the sewer pipelines doubled the CH 4 emissions. • Application of ultrasonication inside sewer pipelines to reduce the CH 4 emissions. • Ultrasonication reduced CH 4 emissions by 34-56% through biofilm detachment. • Increased ultrasonication intervals led to less CH 4 reduction, suggesting revival.

Environmental Technology & InnovationVol. 40
Inha University (KR), Korea Institute of Civil Engineering and Building Technology (KR)
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 14%
Water Systems and Optimization
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.