Non-invasive quantitative assessment of urethral compliance in rabbit tubularized incised plate model using ultrasound and uroflowmetry

Low urinary flow rates are frequently observed following tubularized incised plate urethroplasty. The underlying cause is not yet fully understood and may be associated with low urethral compliance. The purpose of this study is to non-invasively evaluate the urethral compliance in a rabbit model. Ten male New Zealand rabbits were randomly divided into a control group and a urethroplasty group for tubularized incised plate urethroplasty. Seven weeks post-operatively, ex vivo urethral compliance was evaluated using both the Jesus invasive measurement and the non-invasive method. The Jesus measurement involved measuring urethral volume and pressure by air insufflation, and the non-invasive method utilized ultrasound and uroflowmetry to assess the urethral anterior-posterior diameter and flow data, respectively. Curve regression analysis was applied to calculate urethral compliance. Curve regression analysis revealed that the median urethral compliance measured by non-invasive method in the control group was 0.247 (0.241, 0.257) mm•s/ml, and it was 0.269 (0.263, 0.270) mm•s/ml in the urethroplasty group, with no significant difference between the two groups. The Jesus method indicated median urethral compliance was 0.141 (0.137, 0.149) ml/cmH<sub>2</sub>O for the control group and 0.182 (0.173, 0.192) ml/cmH<sub>2</sub>O for the urethroplasty group, showing no significant statistical difference. In the rabbit model, urinary flow rate and anterior-posterior diameter serve as non-invasive indicators that can effectively reflect urethral compliance, and TIP surgery has no significant impact on urethral compliance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-07-20
DOI
https://doi.org/10.1038/s41598-025-11701-8
Primary Topic
Urological Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-invasive quantitative assessment of urethral compliance in rabbit tubularized incised plate model using ultrasound and uroflowmetry

Juan Zhou, Wei Ru, Guangjie Chen, Weifeng Yang et al.
Scientific Reports
Urological Disorders and Treatments
article

Non-invasive quantitative assessment of urethral compliance in rabbit tubularized incised plate model using ultrasound and uroflowmetry

Juan Zhou, Wei Ru, Guangjie Chen, Weifeng Yang, Qibo Hu, Xiang Yan, Lei Hu, Hongbo Liu, Chao Feng
article en

Abstract

Low urinary flow rates are frequently observed following tubularized incised plate urethroplasty. The underlying cause is not yet fully understood and may be associated with low urethral compliance. The purpose of this study is to non-invasively evaluate the urethral compliance in a rabbit model. Ten male New Zealand rabbits were randomly divided into a control group and a urethroplasty group for tubularized incised plate urethroplasty. Seven weeks post-operatively, ex vivo urethral compliance was evaluated using both the Jesus invasive measurement and the non-invasive method. The Jesus measurement involved measuring urethral volume and pressure by air insufflation, and the non-invasive method utilized ultrasound and uroflowmetry to assess the urethral anterior-posterior diameter and flow data, respectively. Curve regression analysis was applied to calculate urethral compliance. Curve regression analysis revealed that the median urethral compliance measured by non-invasive method in the control group was 0.247 (0.241, 0.257) mm•s/ml, and it was 0.269 (0.263, 0.270) mm•s/ml in the urethroplasty group, with no significant difference between the two groups. The Jesus method indicated median urethral compliance was 0.141 (0.137, 0.149) ml/cmH<sub>2</sub>O for the control group and 0.182 (0.173, 0.192) ml/cmH<sub>2</sub>O for the urethroplasty group, showing no significant statistical difference. In the rabbit model, urinary flow rate and anterior-posterior diameter serve as non-invasive indicators that can effectively reflect urethral compliance, and TIP surgery has no significant impact on urethral compliance.

Scientific ReportsVol. 15(1)
Children's Hospital of Zhejiang University (CN)
National Natural Science Foundation of China, Zhejiang Chinese Medical University, National Institutes of Health, Science and Technology Department of Zhejiang Province, Zhejiang Province Public Welfare Technology Application Research Project
Openalex Percentile: Top 75%
Urological Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.