Analysis of occupational radiation doses in nuclear medicine and radiography students during clinical training

An analysis compared the occupational radiation doses received by Nuclear Medicine Technologist (NMT) and radiography students during their clinical training at an Australian University from 2017 to 2020. Utilising Optically Stimulated Luminescence dosemeters to measure the personal dose equivalent, the retrospective cohort included students with dose readings above 100 μSv per monitoring period. Of the total number of students monitored, ~68% received doses below the minimum reportable threshold of 100 μSv per monitoring period, suggesting that most students had minimal exposure during their placements. A chi-square test revealed a significant difference between NMT and radiography students in the proportion of doses below this threshold (Hp(10): χ2(1, N = 1367) = 168.24, P < .001; Hp(0.07): χ2(1, N = 1367) = 139.27, P < .001). Analysing doses above this threshold revealed that NMT students had significantly higher median radiation doses than radiography students, with median Hp(10) doses of 161 μSv versus 130 μSv, respectively (P < .001). Year-to-year analysis indicated that NMT student doses remained stable over the study period, while radiography student doses varied significantly. Comparison with hospital staff doses showed that NMT students received significantly lower doses than professional NMTs (P < .001), whereas radiography students received higher doses than professional radiographers (P < .001). After limiting hospital staff doses to include those only above 100 μSv in a reporting period, radiography students still received higher doses than professional radiographers. The elevated exposure among NMT students compared to radiography students however, emphasizes the need for enhanced radiation protection strategies in nuclear medicine education, emphasising specialized training and regular dose assessments to ensure student safety without compromising educational quality.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-06-30
DOI
https://doi.org/10.1093/rpd/ncaf083
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of occupational radiation doses in nuclear medicine and radiography students during clinical training

Pradip Deb, Mohamed Khaldoun Badawy, George Rouvalis
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Analysis of occupational radiation doses in nuclear medicine and radiography students during clinical training

Pradip Deb, Mohamed Khaldoun Badawy, George Rouvalis
article en

Abstract

An analysis compared the occupational radiation doses received by Nuclear Medicine Technologist (NMT) and radiography students during their clinical training at an Australian University from 2017 to 2020. Utilising Optically Stimulated Luminescence dosemeters to measure the personal dose equivalent, the retrospective cohort included students with dose readings above 100 μSv per monitoring period. Of the total number of students monitored, ~68% received doses below the minimum reportable threshold of 100 μSv per monitoring period, suggesting that most students had minimal exposure during their placements. A chi-square test revealed a significant difference between NMT and radiography students in the proportion of doses below this threshold (Hp(10): χ2(1, N = 1367) = 168.24, P < .001; Hp(0.07): χ2(1, N = 1367) = 139.27, P < .001). Analysing doses above this threshold revealed that NMT students had significantly higher median radiation doses than radiography students, with median Hp(10) doses of 161 μSv versus 130 μSv, respectively (P < .001). Year-to-year analysis indicated that NMT student doses remained stable over the study period, while radiography student doses varied significantly. Comparison with hospital staff doses showed that NMT students received significantly lower doses than professional NMTs (P < .001), whereas radiography students received higher doses than professional radiographers (P < .001). After limiting hospital staff doses to include those only above 100 μSv in a reporting period, radiography students still received higher doses than professional radiographers. The elevated exposure among NMT students compared to radiography students however, emphasizes the need for enhanced radiation protection strategies in nuclear medicine education, emphasising specialized training and regular dose assessments to ensure student safety without compromising educational quality.

Radiation Protection DosimetryVol. 201(12)
Monash Medical Centre (AU), Monash Health (AU), Monash University (AU), RMIT University (AU)
Quality Education
Openalex Percentile: Top 74%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.