Optimised RFO tuned RF-DETR model for precision urine microscopy for renal and systemic disease diagnosis

Accurate detection and classification of cellular and non-cellular components in urine microscopy images are essential for early diagnosis of renal and systemic health conditions. This study presents an optimized object detection framework based on the Red Fox Optimization (RFO)-enabled Roboflow-DEtection TRansformer (RF-DETR) model, designed to automate urine sediment analysis with high precision and low latency. The RF-DETR model leverages a transformer-based architecture with deformable attention and a DINOv2 (self-distillation with no labels) pre-trained visual backbone to capture multi-scale features effectively. RFO, a nature-inspired metaheuristic, is employed to fine-tune critical hyperparameters such as learning rate, decoder layers, and dropout, enhancing the model's convergence and generalization capabilities. Experiments were conducted on the RF100-VL urine microscopy dataset, where the proposed model achieved a precision of 0.78, recall of 0.66, [email protected] of 0.737, and [email protected]:0.95 of 0.44 after 100 training epochs. Compared to baseline models, the optimized RF-DETR demonstrated improved performance in detecting small and medium objects like leukocytes and erythrocytes-crucial components for urinary tract infection and kidney disease detection. The model's NMS-free design and multi-resolution training enable real-time inference on both GPU and edge devices. Additionally, visualization tools such as confusion matrices, F1-curves, and prediction overlays validate the robustness and interpretability of the system. The results confirm the suitability of the RFO-optimized RF-DETR framework for clinical deployment, offering a powerful tool for automated, scalable, and accurate urine analysis. Future work will focus on lightweight model variants, enhanced small-object detection, and domain adaptation using self-supervised and vision-language learning techniques.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-07-16
DOI
https://doi.org/10.1038/s41598-025-11725-0
Citations
3
Primary Topic
Advanced Neural Network Applications
Type
article
Field-Weighted Citation Impact
3.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimised RFO tuned RF-DETR model for precision urine microscopy for renal and systemic disease diagnosis

Shakti Kundu, Manel Ayadi, Deo Prakash, Neeraj Dahiya et al.
3 citations
Scientific Reports
Advanced Neural Network Applications
3.83
article

Optimised RFO tuned RF-DETR model for precision urine microscopy for renal and systemic disease diagnosis

Shakti Kundu, Manel Ayadi, Deo Prakash, Neeraj Dahiya, Shanu Rakesh Kuttan, Arshad Hashmi, Isha Suwalka, Mitiku Dubale
article en
3 citations

Abstract

Accurate detection and classification of cellular and non-cellular components in urine microscopy images are essential for early diagnosis of renal and systemic health conditions. This study presents an optimized object detection framework based on the Red Fox Optimization (RFO)-enabled Roboflow-DEtection TRansformer (RF-DETR) model, designed to automate urine sediment analysis with high precision and low latency. The RF-DETR model leverages a transformer-based architecture with deformable attention and a DINOv2 (self-distillation with no labels) pre-trained visual backbone to capture multi-scale features effectively. RFO, a nature-inspired metaheuristic, is employed to fine-tune critical hyperparameters such as learning rate, decoder layers, and dropout, enhancing the model's convergence and generalization capabilities. Experiments were conducted on the RF100-VL urine microscopy dataset, where the proposed model achieved a precision of 0.78, recall of 0.66, [email protected] of 0.737, and [email protected]:0.95 of 0.44 after 100 training epochs. Compared to baseline models, the optimized RF-DETR demonstrated improved performance in detecting small and medium objects like leukocytes and erythrocytes-crucial components for urinary tract infection and kidney disease detection. The model's NMS-free design and multi-resolution training enable real-time inference on both GPU and edge devices. Additionally, visualization tools such as confusion matrices, F1-curves, and prediction overlays validate the robustness and interpretability of the system. The results confirm the suitability of the RFO-optimized RF-DETR framework for clinical deployment, offering a powerful tool for automated, scalable, and accurate urine analysis. Future work will focus on lightweight model variants, enhanced small-object detection, and domain adaptation using self-supervised and vision-language learning techniques.

Scientific ReportsVol. 15(1)
Princess Nourah bint Abdulrahman University (SA), King Abdulaziz University (SA), Indira Gandhi Government Medical College & Hospital (IN), NIIT University (IN), SRM University (IN), Pandit Sundarlal Sharma Open University (IN), Shri Mata Vaishno Devi University (IN)
Princess Nourah Bint Abdulrahman University
Openalex Percentile: Top 6%
Advanced Neural Network Applications
3.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.