Detection of low-energy backscattered electron in scanning electron microscopy using microchannel plate detector

Si-photodiode is commonly used for the backscattered electron (BSE) detector in scanning electron microscope (SEM). However, it is difficult to detect low-energy electrons below 3 kV. We have developed a thin microchannel plate (MCP) chip with an energy filter grid as an alternative BSE detector for low-energy SEM observations. The MCP can get enough signals even at 1 keV electron beam operation. The energy filtering operation revealed that the MCP image is composed of SE and BSE signals. By filtering SE component, the low-energy BSE images are easily obtained, which will open-up the new observation method of SEM using low-BSE image.

Authors

Institutions

Publication Details

Journal
Microscopy
Published
2025-07-16
DOI
https://doi.org/10.1093/jmicro/dfaf033
Citations
1
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of low-energy backscattered electron in scanning electron microscopy using microchannel plate detector

Takashi Sekiguchi, Yuanzhao Yao, H. Yamamoto, Y. Yanagihara
1 citations
Microscopy
Electron and X-Ray Spectroscopy Techniques
0.66
article

Detection of low-energy backscattered electron in scanning electron microscopy using microchannel plate detector

Takashi Sekiguchi, Yuanzhao Yao, H. Yamamoto, Y. Yanagihara
article en
1 citations

Abstract

Si-photodiode is commonly used for the backscattered electron (BSE) detector in scanning electron microscope (SEM). However, it is difficult to detect low-energy electrons below 3 kV. We have developed a thin microchannel plate (MCP) chip with an energy filter grid as an alternative BSE detector for low-energy SEM observations. The MCP can get enough signals even at 1 keV electron beam operation. The energy filtering operation revealed that the MCP image is composed of SE and BSE signals. By filtering SE component, the low-energy BSE images are easily obtained, which will open-up the new observation method of SEM using low-BSE image.

MicroscopyVol. 75(1)
University of Tsukuba (JP), Graduate School for the Creation of New Photonics Industries (JP)
Affordable and clean energy
Openalex Percentile: Top 30%
Electron and X-Ray Spectroscopy Techniques
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.