Evaluating Artificial Intelligence–Assisted Prostate Biparametric MRI Interpretation: An International Multireader Study

<b>BACKGROUND</b>. Variability in prostate biparametric MRI (bpMRI) interpretation limits diagnostic reliability for prostate cancer (PCa). Artificial intelligence (AI) has the potential to reduce this variability and improve diagnostic accuracy. <b>OBJECTIVE</b>. The objective of this study was to evaluate the impact of a deep learning AI model on lesion- and patient-level rates of detection of PCa and clinically significant PCa (csPCa) and interreader agreement for bpMRI interpretations. <b>METHODS</b>. This retrospective, multireader, multicenter study used a balanced incomplete block design for MRI randomization. Six radiologists of varying experience interpreted bpMRI scans with and without AI assistance in alternating sessions. The reference standard for lesion-level detection for cases was whole-mount pathology after radical prostatectomy; for control patients, it was negative 12-core systematic biopsies. In all, 180 patients (120 in the case group and 60 in the control group) who underwent mpMRI and prostate biopsy or radical prostatectomy between January 2013 and December 2022 were included. Lesion-level sensitivity, PPV, and patient-level AUC for csPCa and PCa detection and interreader agreement for lesion-level PI-RADS scores and size measurements were assessed. <b>RESULTS</b>. AI assistance improved lesion-level PPV (PI-RADS ≥ 3: 77.2% [95% CI, 71.0-83.1%] vs 67.2% [95% CI, 61.1-72.2%] for csPCa; 80.9% [75.2-85.7%] vs 69.4% [95% CI, 63.4-74.1%] for PCa; both <i>p</i> < .001), reduced lesion-level sensitivity (PI-RADS ≥ 3: 44.4% [95% CI, 38.6-50.5%] vs 48.0% [95% CI, 42.0-54.2%] for csPCa; <i>p</i> = .01; 41.7% [95% CI, 37.0-47.4%] vs 44.9% [95% CI, 40.5-50.2%] for PCa; <i>p</i> = .01), and no difference in patient-level AUC (0.822 [95% CI, 0.768-0.866] vs 0.832 [95% CI, 0.787-0.868] for csPCa; <i>p</i> = .61; 0.833 [0.782-0.874] vs 0.835 [95% CI, 0.792-0.871] for PCa; <i>p</i> = .91). AI assistance improved interreader agreement for lesion-level PI-RADS scores (κ = 0.748 [95% CI, 0.701-0.796] vs 0.336 [95% CI, 0.288-0.381]; <i>p</i> < .001), lesion size measurements (coverage probability of 0.397 [95% CI, 0.376-0.419] vs 0.367 [95% CI, 0.349-0.383]; <i>p</i> < .001), and patient-level PI-RADS scores (κ = 0.704 [95% CI, 0.627-0.767] vs 0.507 [95% CI, 0.421-0.584]; <i>p</i> < .001). <b>CONCLUSION</b>. AI improved lesion-level PPV and interreader agreement with slightly lower lesion-level sensitivity. <b>CLINICAL IMPACT</b>. AI may enhance consistency and reduce false-positives in bpMRI interpretations. Further optimization is required to improve sensitivity without compromising specificity.

Authors

Institutions

Publication Details

Journal
American Journal of Roentgenology
Published
2025-07-16
DOI
https://doi.org/10.2214/ajr.24.32399
Citations
3
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
4.56
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Artificial Intelligence–Assisted Prostate Biparametric MRI Interpretation: An International Multireader Study

Ömer Tarık Esengür, Sandeep Gurram, Jamie Marko, Erich P. Huang et al.
3 citations
American Journal of Roentgenology
Prostate Cancer Diagnosis and Treatment
4.56
article

Evaluating Artificial Intelligence–Assisted Prostate Biparametric MRI Interpretation: An International Multireader Study

Ömer Tarık Esengür, Sandeep Gurram, Jamie Marko, Erich P. Huang, David G. Gelikman, Julie Y. An, Valeria Panebianco, Marco Bicchetti, Maria J. Merino, Bradford J. Wood, Yue Lin, Jesse Tetreault, Ziyue Xu, Nathan Lay, Enis C. Yılmaz, Dong Liang Yang, Daguang Xu, Joanna H. Shih, Rosina T. Lis, Stephanie A. Harmon, Peter L. Choyke, Sonia Gaur, Mason J. Belue, Yan Mee Law, Sena Azamat, Peter Pinto, Daniel J. A. Margolis, Barış Türkbey
article en
3 citations

Abstract

<b>BACKGROUND</b>. Variability in prostate biparametric MRI (bpMRI) interpretation limits diagnostic reliability for prostate cancer (PCa). Artificial intelligence (AI) has the potential to reduce this variability and improve diagnostic accuracy. <b>OBJECTIVE</b>. The objective of this study was to evaluate the impact of a deep learning AI model on lesion- and patient-level rates of detection of PCa and clinically significant PCa (csPCa) and interreader agreement for bpMRI interpretations. <b>METHODS</b>. This retrospective, multireader, multicenter study used a balanced incomplete block design for MRI randomization. Six radiologists of varying experience interpreted bpMRI scans with and without AI assistance in alternating sessions. The reference standard for lesion-level detection for cases was whole-mount pathology after radical prostatectomy; for control patients, it was negative 12-core systematic biopsies. In all, 180 patients (120 in the case group and 60 in the control group) who underwent mpMRI and prostate biopsy or radical prostatectomy between January 2013 and December 2022 were included. Lesion-level sensitivity, PPV, and patient-level AUC for csPCa and PCa detection and interreader agreement for lesion-level PI-RADS scores and size measurements were assessed. <b>RESULTS</b>. AI assistance improved lesion-level PPV (PI-RADS ≥ 3: 77.2% [95% CI, 71.0-83.1%] vs 67.2% [95% CI, 61.1-72.2%] for csPCa; 80.9% [75.2-85.7%] vs 69.4% [95% CI, 63.4-74.1%] for PCa; both <i>p</i> < .001), reduced lesion-level sensitivity (PI-RADS ≥ 3: 44.4% [95% CI, 38.6-50.5%] vs 48.0% [95% CI, 42.0-54.2%] for csPCa; <i>p</i> = .01; 41.7% [95% CI, 37.0-47.4%] vs 44.9% [95% CI, 40.5-50.2%] for PCa; <i>p</i> = .01), and no difference in patient-level AUC (0.822 [95% CI, 0.768-0.866] vs 0.832 [95% CI, 0.787-0.868] for csPCa; <i>p</i> = .61; 0.833 [0.782-0.874] vs 0.835 [95% CI, 0.792-0.871] for PCa; <i>p</i> = .91). AI assistance improved interreader agreement for lesion-level PI-RADS scores (κ = 0.748 [95% CI, 0.701-0.796] vs 0.336 [95% CI, 0.288-0.381]; <i>p</i> < .001), lesion size measurements (coverage probability of 0.397 [95% CI, 0.376-0.419] vs 0.367 [95% CI, 0.349-0.383]; <i>p</i> < .001), and patient-level PI-RADS scores (κ = 0.704 [95% CI, 0.627-0.767] vs 0.507 [95% CI, 0.421-0.584]; <i>p</i> < .001). <b>CONCLUSION</b>. AI improved lesion-level PPV and interreader agreement with slightly lower lesion-level sensitivity. <b>CLINICAL IMPACT</b>. AI may enhance consistency and reduce false-positives in bpMRI interpretations. Further optimization is required to improve sensitivity without compromising specificity.

American Journal of RoentgenologyVol. 225(6)
Brigham and Women's Hospital (US), National Institutes of Health (US), Johns Hopkins University (US), Cornell University (US), Singapore General Hospital (SG), University of California San Diego (US), Nvidia (United States) (US), Istanbul Eye Hospital (TR), National Cancer Institute (US), Sapienza University of Rome (IT)
Openalex Percentile: Top 5%
Prostate Cancer Diagnosis and Treatment
4.56
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.