Impact of Beam Clipping and Size on Focused Laser Differential Interferometry in Hypersonic Disturbance Measurements

The sensitivity and spatial resolution of focused laser differential interferometry (FLDI) improve with a lower f-number, indicating that a larger beam diameter on the field lens is beneficial. However, when testing a wider flat plate model and probing within the boundary layer, the FLDI beam often gets clipped at the model's edge. This paper investigates the FLDI system’s response with a clipped beam, reduced beam diameter and modified beam shape through experiments conducted in the T4 Staker tube, measuring free stream disturbances and second-mode instabilities. Free stream results show a mere change in the signal-to-noise ratio and turbulent-based intensity values for the clipped and smaller diameter beam compared to an unclipped one, despite a change in the spectral slope. Nevertheless, information like second-mode frequencies is preserved and accurately measured for the unconventional FLDI systems. Validation against spectra from a modified cylindrical FLDI technique and higher energy mode images from modal analysis supports these findings. An FLDI system with a simple modification from spherical to elliptical beam would be helpful in future studies when a wider model is used instead of a complex cylindrical FLDI system.

Authors

Institutions

Publication Details

Published
2025-07-16
DOI
https://doi.org/10.2514/6.2025-3724
Primary Topic
Gas Dynamics and Kinetic Theory
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Beam Clipping and Size on Focused Laser Differential Interferometry in Hypersonic Disturbance Measurements

Ramprakash Ananthapadmanaban, D. J. Mee, Ananthanarayanan Veeraragavan, Matthew A. Trudgian
Gas Dynamics and Kinetic Theory
article

Impact of Beam Clipping and Size on Focused Laser Differential Interferometry in Hypersonic Disturbance Measurements

Ramprakash Ananthapadmanaban, D. J. Mee, Ananthanarayanan Veeraragavan, Matthew A. Trudgian
article en

Abstract

The sensitivity and spatial resolution of focused laser differential interferometry (FLDI) improve with a lower f-number, indicating that a larger beam diameter on the field lens is beneficial. However, when testing a wider flat plate model and probing within the boundary layer, the FLDI beam often gets clipped at the model's edge. This paper investigates the FLDI system’s response with a clipped beam, reduced beam diameter and modified beam shape through experiments conducted in the T4 Staker tube, measuring free stream disturbances and second-mode instabilities. Free stream results show a mere change in the signal-to-noise ratio and turbulent-based intensity values for the clipped and smaller diameter beam compared to an unclipped one, despite a change in the spectral slope. Nevertheless, information like second-mode frequencies is preserved and accurately measured for the unconventional FLDI systems. Validation against spectra from a modified cylindrical FLDI technique and higher energy mode images from modal analysis supports these findings. An FLDI system with a simple modification from spherical to elliptical beam would be helpful in future studies when a wider model is used instead of a complex cylindrical FLDI system.

The University of Queensland (AU)
Climate action
Openalex Percentile: Top 74%
Gas Dynamics and Kinetic Theory
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.