Y2O3-Doped BioGlass Coatings for Ti-6Al-4V Alloy: Insights into Degradation, Bioactivity, Ion Release, Adhesion, and Corrosion Behavior

Abstract The Ti-6Al-4V alloy is particularly favored for orthopedic applications. However, important issues such as corrosion resistance, biocompatibility, and ion release need to be addressed. Therefore, this study aims to enhance the corrosion resistance and biocompatibility and reduce the ion release of the Ti-6Al-4V alloy by applying Y 2 O 3 -doped bioglass bioceramic coatings. The coatings were synthesized using the sol-gel method, including pure BioGlass and BioGlass with 1, 5, and 10 wt pct Y 2 O 3 . These coatings were then evaluated for their corrosion resistance, adhesion strength, degradation behavior, bioactivity, and ion release. The results showed that all coatings exhibited homogeneous, crack-free, and porous morphologies, which are favorable for osteointegration. The addition of 10 wt pct Y 2 O 3 to the BioGlass coating resulted in a 52 pct increment in adhesion strength, which increased from 13.72 ± 2.80 MPa for single BioGlass coatings to 20.81 ± 2.53 MPa. All samples showed degradation values lower than 1 wt pct. Single BioGlass coatings significantly enhanced the bioactivity of Ti-6Al-4V alloy. However, the addition of Y 2 O 3 negatively impacted BioGlass bioactivity, leading to a noticeable decrease as the Y 2 O 3 content increased. Conversely, the presence of Y 2 O 3 negatively impacted bioactivity and corrosion resistance while increasing the release of Ti ions. Specifically, the release of Ti ions increased from 79.5 ± 0.8 ppb in uncoated samples to 253.7 ± 15.3 ppb in BG-coated samples. For 1, 5, and 10 pct Y 2 O 3 -added samples, Ti releases were measured as 192.2 ± 33.6 ppb, 168.5 ± 62.4 ppb, and 194.3 ± 54.4 ppb, respectively. This research highlights the potential of tailored BioGlass coatings to improve the performance of Ti-6Al-4V alloys in orthopedic implant applications, particularly for enhancing bone integration and reducing implant failure.

Authors

Institutions

Publication Details

Journal
Metallurgical and Materials Transactions A
Published
2025-07-16
DOI
https://doi.org/10.1007/s11661-025-07896-0
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Y2O3-Doped BioGlass Coatings for Ti-6Al-4V Alloy: Insights into Degradation, Bioactivity, Ion Release, Adhesion, and Corrosion Behavior

Salih Cihangir, Yakup Say, Ulaş Çaydaş, Naim Aslan et al.
1 citations
Metallurgical and Materials Transactions A
Bone Tissue Engineering Materials
0.67
article

Y2O3-Doped BioGlass Coatings for Ti-6Al-4V Alloy: Insights into Degradation, Bioactivity, Ion Release, Adhesion, and Corrosion Behavior

Salih Cihangir, Yakup Say, Ulaş Çaydaş, Naim Aslan, Oğuzkağan Murat
article en
1 citations

Abstract

Abstract The Ti-6Al-4V alloy is particularly favored for orthopedic applications. However, important issues such as corrosion resistance, biocompatibility, and ion release need to be addressed. Therefore, this study aims to enhance the corrosion resistance and biocompatibility and reduce the ion release of the Ti-6Al-4V alloy by applying Y 2 O 3 -doped bioglass bioceramic coatings. The coatings were synthesized using the sol-gel method, including pure BioGlass and BioGlass with 1, 5, and 10 wt pct Y 2 O 3 . These coatings were then evaluated for their corrosion resistance, adhesion strength, degradation behavior, bioactivity, and ion release. The results showed that all coatings exhibited homogeneous, crack-free, and porous morphologies, which are favorable for osteointegration. The addition of 10 wt pct Y 2 O 3 to the BioGlass coating resulted in a 52 pct increment in adhesion strength, which increased from 13.72 ± 2.80 MPa for single BioGlass coatings to 20.81 ± 2.53 MPa. All samples showed degradation values lower than 1 wt pct. Single BioGlass coatings significantly enhanced the bioactivity of Ti-6Al-4V alloy. However, the addition of Y 2 O 3 negatively impacted BioGlass bioactivity, leading to a noticeable decrease as the Y 2 O 3 content increased. Conversely, the presence of Y 2 O 3 negatively impacted bioactivity and corrosion resistance while increasing the release of Ti ions. Specifically, the release of Ti ions increased from 79.5 ± 0.8 ppb in uncoated samples to 253.7 ± 15.3 ppb in BG-coated samples. For 1, 5, and 10 pct Y 2 O 3 -added samples, Ti releases were measured as 192.2 ± 33.6 ppb, 168.5 ± 62.4 ppb, and 194.3 ± 54.4 ppb, respectively. This research highlights the potential of tailored BioGlass coatings to improve the performance of Ti-6Al-4V alloys in orthopedic implant applications, particularly for enhancing bone integration and reducing implant failure.

Metallurgical and Materials Transactions AVol. 56(9)
University of Turku (FI), Munzur University (TR)
Munzur Üniversitesi
Clean water and sanitation
Openalex Percentile: Top 29%
Bone Tissue Engineering Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.