Modelling and Performance Analysis of DFIG Integrated with LMF-PLL under Grid Abnormalities

Recently wind’s energy has increased access in the electric grid that makes it vital to develop and test adequate acceptable electromechanical the wind turbine generator (WTG) models for analysing the effects of wind integration on the transient stability of the power system. A Doubly-Fed Induction Generator DFIG (asynchronous wound rotor turbine) integrated with Least Mean Fourth Phase Locked Loop (LMF-PLL) model is discussed in this paper. The modelling and the analysing of LMF-PLL integrated DFIG is carried out while considering different grid abnormalities like voltage dip (30%), phase angle jump (20°), frequency change (+3Hz), dc offset (10%) with polluted environment. Moreover, the performance of the integrated system is studied to observe its behaviour under varying rotational speed. The simulation performance of DFIG system integrated with the LMF-PLL under grid abnormalities is performed in Matlab/Simulink environment.

Authors

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/pectea61788.2025.11076272
Citations
1
Primary Topic
Advanced Adaptive Filtering Techniques
Type
article
Field-Weighted Citation Impact
1.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modelling and Performance Analysis of DFIG Integrated with LMF-PLL under Grid Abnormalities

Alka Singh, Oinam Lotika Devi
1 citations
Advanced Adaptive Filtering Techniques
1.33
article

Modelling and Performance Analysis of DFIG Integrated with LMF-PLL under Grid Abnormalities

Alka Singh, Oinam Lotika Devi
article en
1 citations

Abstract

Recently wind’s energy has increased access in the electric grid that makes it vital to develop and test adequate acceptable electromechanical the wind turbine generator (WTG) models for analysing the effects of wind integration on the transient stability of the power system. A Doubly-Fed Induction Generator DFIG (asynchronous wound rotor turbine) integrated with Least Mean Fourth Phase Locked Loop (LMF-PLL) model is discussed in this paper. The modelling and the analysing of LMF-PLL integrated DFIG is carried out while considering different grid abnormalities like voltage dip (30%), phase angle jump (20°), frequency change (+3Hz), dc offset (10%) with polluted environment. Moreover, the performance of the integrated system is studied to observe its behaviour under varying rotational speed. The simulation performance of DFIG system integrated with the LMF-PLL under grid abnormalities is performed in Matlab/Simulink environment.

Delhi Technological University (IN)
Affordable and clean energy
Openalex Percentile: Top 21%
Advanced Adaptive Filtering Techniques
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modelling and Performance Analysis of DFIG Integrated with LMF-PLL under Grid Abnormalities — Alka Singh, Oinam Lotika Devi · (2025) | TGRS Research Map | TGRS