Electromagnetic Emission Estimation Using Common-Mode Current for Arc Fault Detection in Low Voltage Systems

Arcing faults are a major cause of electrical fires in low-voltage distribution systems. Early detection of these faults is essential to improve system safety and reliability. This paper proposes a method to estimate radiated electromagnetic emissions (EME) generated by arc discharges using common-mode currents induced in conductors. A high-frequency current sensor captures these currents, which are modeled using a Hertzian dipole framework to predict far-field radiation. Experimental validation was conducted using broadband antenna measurements at two distances in the far field. The results show a strong agreement with the theoretical predictions, confirming the ability of the model to reproduce the spatial decay and spectral characteristics of the arc-induced emissions. The proposed approach provides a practical, non-intrusive technique for arc fault detection in low-voltage power systems.

Authors

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/pectea61788.2025.11076471
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electromagnetic Emission Estimation Using Common-Mode Current for Arc Fault Detection in Low Voltage Systems

Aurobinda Routray, Ashok Kumar Pradhan, Ratnakar Nutenki
Electrical Fault Detection and Protection
article

Electromagnetic Emission Estimation Using Common-Mode Current for Arc Fault Detection in Low Voltage Systems

Aurobinda Routray, Ashok Kumar Pradhan, Ratnakar Nutenki
article en

Abstract

Arcing faults are a major cause of electrical fires in low-voltage distribution systems. Early detection of these faults is essential to improve system safety and reliability. This paper proposes a method to estimate radiated electromagnetic emissions (EME) generated by arc discharges using common-mode currents induced in conductors. A high-frequency current sensor captures these currents, which are modeled using a Hertzian dipole framework to predict far-field radiation. Experimental validation was conducted using broadband antenna measurements at two distances in the far field. The results show a strong agreement with the theoretical predictions, confirming the ability of the model to reproduce the spatial decay and spectral characteristics of the arc-induced emissions. The proposed approach provides a practical, non-intrusive technique for arc fault detection in low-voltage power systems.

Indian Institute of Technology Kharagpur (IN), Rajiv Gandhi University of Knowledge Technologies (IN)
Affordable and clean energy
Openalex Percentile: Top 84%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.