Simulation research on bone imaging using x-ray induced acoustic computed tomography with a semicircular array

X-ray induced acoustic computed tomography (XACT) is a cutting-edge imaging technique that capitalizes on the thermoelastic effect. It offers the advantages of low X-ray radiation dose and high resolution. In the context of this study, a semicircular array was incorporated into the XACT technique for the evaluation of bone imaging. To optimize the XACT process, semicircular arrays with various element configurations were integrated into the simulation. This integration is conducive to determining the optimal number of elements that can achieve the best image quality. Furthermore, the XACT simulation images of bones were presented and compared with those obtained from computed tomography (CT). The results of the comparative analysis indicate that the XACT images are highly consistent with the CT images and can clearly depict the microstructures of bones. Evidently, the XACT technique holds potential application prospects in the field of bone imaging.

Authors

Institutions

Publication Details

Published
2025-07-16
DOI
https://doi.org/10.1117/12.3070786
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation research on bone imaging using x-ray induced acoustic computed tomography with a semicircular array

Shihua Zhao, Ningning Su, Chenglong Du, Jingxu Jin
1 links
Flow Measurement and Analysis
article

Simulation research on bone imaging using x-ray induced acoustic computed tomography with a semicircular array

Shihua Zhao, Ningning Su, Chenglong Du, Jingxu Jin
article en

Abstract

X-ray induced acoustic computed tomography (XACT) is a cutting-edge imaging technique that capitalizes on the thermoelastic effect. It offers the advantages of low X-ray radiation dose and high resolution. In the context of this study, a semicircular array was incorporated into the XACT technique for the evaluation of bone imaging. To optimize the XACT process, semicircular arrays with various element configurations were integrated into the simulation. This integration is conducive to determining the optimal number of elements that can achieve the best image quality. Furthermore, the XACT simulation images of bones were presented and compared with those obtained from computed tomography (CT). The results of the comparative analysis indicate that the XACT images are highly consistent with the CT images and can clearly depict the microstructures of bones. Evidently, the XACT technique holds potential application prospects in the field of bone imaging.

Shandong University of Technology (CN)
Openalex Percentile: Top 81%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation research on bone imaging using x-ray induced acoustic computed tomography with a semicircular array — Shihua Zhao, Ningning Su, et al. · (2025) | TGRS Research Map | TGRS