Bistatic FDA radar hypersonic target detection

Frequency diversity array (FDA) has a wide range of application potentials in target detection, interference suppression and other fields. Compared with monostatic radar, bistatic radar can detect weak targets by utilizing the scattering of targets in different directions. Therefore, combining characteristics of the bistatic radar and FDA can significantly improve the target detection performance. However, when observing hypersonic targets for a long time, range migration and Doppler shift will occur, and the coherent integration performance will decrease. To address this problem, this paper analyzes the influence of the additional doppler shift caused by the frequency increment and velocity, then a range walk compensation method is proposed for bistatic FDA radar based on Keystone transform. Finally, simulations demonstrate the theoretical analysis, and the proposed method has reliable detection outcomes.

Authors

Institutions

Publication Details

Published
2025-07-16
DOI
https://doi.org/10.1117/12.3070785
Primary Topic
Advanced SAR Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bistatic FDA radar hypersonic target detection

Wanzhao Cui, Langtao Bai, Weiwei Wang, Jiale Liang
Advanced SAR Imaging Techniques
article

Bistatic FDA radar hypersonic target detection

Wanzhao Cui, Langtao Bai, Weiwei Wang, Jiale Liang
article en

Abstract

Frequency diversity array (FDA) has a wide range of application potentials in target detection, interference suppression and other fields. Compared with monostatic radar, bistatic radar can detect weak targets by utilizing the scattering of targets in different directions. Therefore, combining characteristics of the bistatic radar and FDA can significantly improve the target detection performance. However, when observing hypersonic targets for a long time, range migration and Doppler shift will occur, and the coherent integration performance will decrease. To address this problem, this paper analyzes the influence of the additional doppler shift caused by the frequency increment and velocity, then a range walk compensation method is proposed for bistatic FDA radar based on Keystone transform. Finally, simulations demonstrate the theoretical analysis, and the proposed method has reliable detection outcomes.

China Academy of Space Technology (CN), Space Micro (United States) (US)
Openalex Percentile: Top 76%
Advanced SAR Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bistatic FDA radar hypersonic target detection — Wanzhao Cui, Langtao Bai, et al. · (2025) | TGRS Research Map | TGRS