A study on the repeatability of radiomics parameters under repeated CT scans

Abstract Background To investigate the repeatability and diagnostic ability of radiomics parameters of lung lesions under repeated CT scan. Methods A retrospective analysis of 101 patients who underwent CT-guided percutaneous biopsy in our hospital and were pathologically confirmed as lung cancer and chronic inflammation. Two images of repeated CT scan in the puncture process were selected. The gray histogram and gray-level co-occurrence matrix of the lesion area were extracted based on ImageJ: mean gray value (mean), gray variance (SD), minimum gray value (minor), maximum gray value (max), Skewness, kurtosis, contrast, correlation, angular second moment (ASM), inverse different moment(IDM), and entropy. Intraclass correlation (ICC) was used to evaluate the repeatability of the measurement results of the two images. Results The parameters with ICC greater than 0.8 were selected, and the average values of the two measurements were taken. The independent sample t test and Mann–Whitney U test were used to compare the difference of radiomics parameters between benign and malignant lesions. Application subjects: Nine parameters with excellent consistency between the two measurements were entropy (ICC: 0.982), IDM (0.975), ASM (0.956), mean (0.902), max (0.841), SD (0.894), correlation (0.878), and minor (0.897). The parameter with good consistency was kurtosis (ICC: 0.784). The parameter with poor consistency was contrast (ICC: 0.577).There were significant differences in IDM, correlation, and entropy between the benign group and the malignant group ( P < 0.05). In ROC curve analysis, correlation had the best diagnostic effect (AUC: 0.749), followed by entropy (AUC: 0.642) and IDM (AUC: 0.617). Conclusion The radiomics parameters of quantitative calculation of CT images under repeated scanning showed good repeatability. The values of entropy, contrast, and correlation have certain clinical diagnostic value in differentiating benign and malignant lung lesions.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2025-07-16
DOI
https://doi.org/10.1186/s43055-025-01508-y
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A study on the repeatability of radiomics parameters under repeated CT scans

Chao Qian, Yin-Bo Feng, Zhigang Min, Lin Wu et al.
The Egyptian Journal of Radiology and Nuclear Medicine
Radiomics and Machine Learning in Medical Imaging
article

A study on the repeatability of radiomics parameters under repeated CT scans

Chao Qian, Yin-Bo Feng, Zhigang Min, Lin Wu, Ting Chen, Yu Zhao
article en

Abstract

Abstract Background To investigate the repeatability and diagnostic ability of radiomics parameters of lung lesions under repeated CT scan. Methods A retrospective analysis of 101 patients who underwent CT-guided percutaneous biopsy in our hospital and were pathologically confirmed as lung cancer and chronic inflammation. Two images of repeated CT scan in the puncture process were selected. The gray histogram and gray-level co-occurrence matrix of the lesion area were extracted based on ImageJ: mean gray value (mean), gray variance (SD), minimum gray value (minor), maximum gray value (max), Skewness, kurtosis, contrast, correlation, angular second moment (ASM), inverse different moment(IDM), and entropy. Intraclass correlation (ICC) was used to evaluate the repeatability of the measurement results of the two images. Results The parameters with ICC greater than 0.8 were selected, and the average values of the two measurements were taken. The independent sample t test and Mann–Whitney U test were used to compare the difference of radiomics parameters between benign and malignant lesions. Application subjects: Nine parameters with excellent consistency between the two measurements were entropy (ICC: 0.982), IDM (0.975), ASM (0.956), mean (0.902), max (0.841), SD (0.894), correlation (0.878), and minor (0.897). The parameter with good consistency was kurtosis (ICC: 0.784). The parameter with poor consistency was contrast (ICC: 0.577).There were significant differences in IDM, correlation, and entropy between the benign group and the malignant group ( P < 0.05). In ROC curve analysis, correlation had the best diagnostic effect (AUC: 0.749), followed by entropy (AUC: 0.642) and IDM (AUC: 0.617). Conclusion The radiomics parameters of quantitative calculation of CT images under repeated scanning showed good repeatability. The values of entropy, contrast, and correlation have certain clinical diagnostic value in differentiating benign and malignant lung lesions.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 56(1)
Jiangsu University (CN), Shanghai Traditional Chinese Medicine Hospital (CN), Yixing Tumor Hospital (CN), Yixing People's Hospital (CN), Wuxi Taihu Hospital (CN)
Openalex Percentile: Top 74%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.