Biodegradable microneedle-based electrodes for electrophysiological measurements

Biopotential recordings such as electroencephalogram (EEG) and electrocardiogram (ECG) generally use wet gel electrodes to ensure a low coupling impedance at the electrode/tissue interface. This set-up is long and tedious and may lead to non-robust signals because of the gel that can leak or dry out. We propose to replace wet gel electrodes with initially dry hydrogel microneedle (MN)-based electrodes capable of piercing the insulating outer layers of the skin and reach the conductive interstitial fluid located in the dermis. Interestingly, purely safe and biodegradable polymer MN tips are able to self-degrade after measurement, increasing safety in the event of microneedle breakage into the skin. We fabricated biocompatible and biodegradable hydrogel-based MN patches made of the cross-linked carboxymethylcellulose (CMC) polymer, rigid and electrically insulating in the dry state, and able to swell once in contact with the ion-conducting interstitial fluid. A metal transduction layer was integrated on the back of the MN patches to obtain the wearable measuring MN-based electrodes. The swelling and ion-conducting capacity of the MN patches were demonstrated. The electrical measurement capability of the MN-based electrodes was assessed using a simple lab-made skin phantom representing the mechanical and electrical properties of the dermis and epidermis. In this proof-of-concept, superior measurement quality was demonstrated with MN-based electrodes in comparison to those of standard wet gel electrodes without any skin preparation. The biodegradable hydrogel-based MN electrodes could therefore offer easy use, patient comfort and safety, and record biopotentials for several hours.

Authors

Institutions

Publication Details

Journal
Journal of Materials Chemistry B
Published
2025-01-01
DOI
https://doi.org/10.1039/d5tb00727e
Citations
6
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
4.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biodegradable microneedle-based electrodes for electrophysiological measurements

Sacha Juillard, Anne Planat‐Chrétien, Isabelle Texier
6 citations
Journal of Materials Chemistry B
Analytical Chemistry and Sensors
4.42
article

Biodegradable microneedle-based electrodes for electrophysiological measurements

Sacha Juillard, Anne Planat‐Chrétien, Isabelle Texier
article en
6 citations

Abstract

Biopotential recordings such as electroencephalogram (EEG) and electrocardiogram (ECG) generally use wet gel electrodes to ensure a low coupling impedance at the electrode/tissue interface. This set-up is long and tedious and may lead to non-robust signals because of the gel that can leak or dry out. We propose to replace wet gel electrodes with initially dry hydrogel microneedle (MN)-based electrodes capable of piercing the insulating outer layers of the skin and reach the conductive interstitial fluid located in the dermis. Interestingly, purely safe and biodegradable polymer MN tips are able to self-degrade after measurement, increasing safety in the event of microneedle breakage into the skin. We fabricated biocompatible and biodegradable hydrogel-based MN patches made of the cross-linked carboxymethylcellulose (CMC) polymer, rigid and electrically insulating in the dry state, and able to swell once in contact with the ion-conducting interstitial fluid. A metal transduction layer was integrated on the back of the MN patches to obtain the wearable measuring MN-based electrodes. The swelling and ion-conducting capacity of the MN patches were demonstrated. The electrical measurement capability of the MN-based electrodes was assessed using a simple lab-made skin phantom representing the mechanical and electrical properties of the dermis and epidermis. In this proof-of-concept, superior measurement quality was demonstrated with MN-based electrodes in comparison to those of standard wet gel electrodes without any skin preparation. The biodegradable hydrogel-based MN electrodes could therefore offer easy use, patient comfort and safety, and record biopotentials for several hours.

Journal of Materials Chemistry BVol. 13(32)
Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), CEA Grenoble (FR), Direction de la Recherche Technologique (FR), Laboratoire d'Électronique des Technologies de l'Information (FR), Université Grenoble Alpes (FR)
LABoratoires d’EXcellence ARCANE, Agence Nationale de la Recherche
Affordable and clean energy
Openalex Percentile: Top 5%
Analytical Chemistry and Sensors
4.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.