Hydrologic analysis and hydraulics design of surface drainage for stormwater: A neglect of vital aspect

The importance of constructing drainage structures for the conveyance of direct runoff to suitable locations has long been identified by man. However, it has been observed that most constructed drainages did not serve the intended purpose during the design period despite being structurally sound with proper maintenance culture. This has been attributed to inadequate or lack of hydrologic analysis and hydraulics design before construction, as most design only consider the structural aspect. Hence, this work considered the hydrologic and hydraulics design of the drainage system of a proposed paved/tarred road, in line with engineering standards. This was achieved by incorporating environmental parameters such as digital elevation model (DEM) and land use-land cover map as well as hydrologic parameters such as composite runoff coefficient, rainfall intensity-duration-frequency (IDF) curves, concentration time and drainage area, in obtaining the expected surface runoff from the Rational Formula. Thereafter, the hydraulics design was done using the well-known Manning’s Equation in accordance with most or best economic section. It was revealed that the catchment area capable of draining direct runoff into the drainage channels is 0.0874km2 while the composite runoff coefficient and concentration time were 0.57 and approximately 120minutes respectively. It was also revealed that the 2.9km drainage on either side of the road will have a channel width of 510mm, flow depth of 255mm in addition to a freeboard space of 51mm and a bed slope of 0.01. The hydraulics designs were checked and it was observed that the design permits a flow velocity of 1.69m/s, which is sufficient for self-cleansing velocity without scouring of the bed and side walls. The engineering drawings of the designed channels were also provided and necessary recommendations were made.

Authors

Institutions

Publication Details

Journal
KIU journal of science engineering and technology
Published
2025-05-25
DOI
https://doi.org/10.59568/kjset-2025-4-1-06
Citations
1
Primary Topic
Urban Stormwater Management Solutions
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrologic analysis and hydraulics design of surface drainage for stormwater: A neglect of vital aspect

Francis James Ogbozige
1 citations
KIU journal of science engineering and technology
Urban Stormwater Management Solutions
0.80
article

Hydrologic analysis and hydraulics design of surface drainage for stormwater: A neglect of vital aspect

Francis James Ogbozige
article en
1 citations

Abstract

The importance of constructing drainage structures for the conveyance of direct runoff to suitable locations has long been identified by man. However, it has been observed that most constructed drainages did not serve the intended purpose during the design period despite being structurally sound with proper maintenance culture. This has been attributed to inadequate or lack of hydrologic analysis and hydraulics design before construction, as most design only consider the structural aspect. Hence, this work considered the hydrologic and hydraulics design of the drainage system of a proposed paved/tarred road, in line with engineering standards. This was achieved by incorporating environmental parameters such as digital elevation model (DEM) and land use-land cover map as well as hydrologic parameters such as composite runoff coefficient, rainfall intensity-duration-frequency (IDF) curves, concentration time and drainage area, in obtaining the expected surface runoff from the Rational Formula. Thereafter, the hydraulics design was done using the well-known Manning’s Equation in accordance with most or best economic section. It was revealed that the catchment area capable of draining direct runoff into the drainage channels is 0.0874km2 while the composite runoff coefficient and concentration time were 0.57 and approximately 120minutes respectively. It was also revealed that the 2.9km drainage on either side of the road will have a channel width of 510mm, flow depth of 255mm in addition to a freeboard space of 51mm and a bed slope of 0.01. The hydraulics designs were checked and it was observed that the design permits a flow velocity of 1.69m/s, which is sufficient for self-cleansing velocity without scouring of the bed and side walls. The engineering drawings of the designed channels were also provided and necessary recommendations were made.

KIU journal of science engineering and technologyVol. 4(1)
Federal University Otuoke (NG)
Openalex Percentile: Top 27%
Urban Stormwater Management Solutions
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Hydrologic analysis and hydraulics design of surface drainage for stormwater: A neglect of vital aspect — Francis James Ogbozige · KIU journal of science engineering and technology (2025) | TGRS Research Map | TGRS