Pulse Oximetry Discrepancies and Occult Hypoxemia in ICU Patients: Predictors and Clinical Outcomes

BackgroundPulse oximeters sometimes fail to accurately reflect arterial oxygen saturation (SaO<sub>2</sub>), particularly in darker-skinned patients resulting in undiagnosed hypoxemia, potentially delaying recognition and appropriate interventions.Research QuestionWe aimed to evaluate the prevalence and predictors of SpO<sub>2</sub>-SaO<sub>2</sub> discrepancies, particularly occult hypoxemia, and to assess their association with clinical outcomes in ICU patients.Study Design and MethodsWe conducted a retrospective cohort analysis using the Blood-gas and Oximetry Linked Dataset (BOLD), analyzing critically ill patients from the eICU-CRD database (2014-2015). Patients with paired SpO<sub>2</sub>-SaO<sub>2</sub> measurements within five minutes were included. We identified SpO<sub>2</sub>-SaO<sub>2</sub> discrepancies as a difference of >2.99% and defined occult hypoxemia as an arterial partial pressure of oxygen (PaO<sub>2</sub>) < 60 mm Hg or SaO<sub>2</sub> < 89% with an SpO<sub>2</sub> > 88%. The primary outcomes included ICU length of stay (LOS), Sequential Organ Failure Assessment (SOFA) score, and in-hospital mortality.ResultsAmong 36,280 ICU patients, 23.6% had SpO<sub>2</sub>-SaO<sub>2</sub> discrepancies, and 4.7% had occult hypoxemia. Black patients were overrepresented in both groups, with an adjusted odds ratio (aOR) of 1.35 (95% CI: 1.25-1.47) for discrepancy and 1.22 (95% CI: 1.04-1.47) for occult hypoxemia. Higher BMI, lower pH, elevated creatinine, and higher Charlson Comorbidity Index scores were also significant predictors. Patients with discrepancies had worse clinical outcomes, including increased SOFA scores in the following 24 h (β = 0.31; <i>p</i> < .0001) and higher in-hospital mortality (aOR 1.15; <i>p</i> < .0001). Occult hypoxemia was associated with even worse outcomes, including a longer ICU LOS (IRR 1.12; <i>p</i> < .0001) and significantly increased mortality (aOR 1.73; <i>p</i> < .0001).InterpretationOne in four critically ill patient in our cohort experienced SpO<sub>2</sub>-SaO<sub>2</sub> discrepancy which is associated with adverse clinical outcomes. Black race, obesity, and higher comorbidity burden were significant predictors of these discrepancies. Our findings emphasize the need for more rigorous clinician oversight in the use of this technology.

Authors

Institutions

Publication Details

Journal
Journal of Intensive Care Medicine
Published
2025-07-16
DOI
https://doi.org/10.1177/08850666251351594
Citations
3
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
6.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse Oximetry Discrepancies and Occult Hypoxemia in ICU Patients: Predictors and Clinical Outcomes

Saqib Baig, Iqbal Ali, SAIKOU O SAIDY
3 citations
Journal of Intensive Care Medicine
Hemodynamic Monitoring and Therapy
6.02
article

Pulse Oximetry Discrepancies and Occult Hypoxemia in ICU Patients: Predictors and Clinical Outcomes

Saqib Baig, Iqbal Ali, SAIKOU O SAIDY
article en
3 citations

Abstract

BackgroundPulse oximeters sometimes fail to accurately reflect arterial oxygen saturation (SaO<sub>2</sub>), particularly in darker-skinned patients resulting in undiagnosed hypoxemia, potentially delaying recognition and appropriate interventions.Research QuestionWe aimed to evaluate the prevalence and predictors of SpO<sub>2</sub>-SaO<sub>2</sub> discrepancies, particularly occult hypoxemia, and to assess their association with clinical outcomes in ICU patients.Study Design and MethodsWe conducted a retrospective cohort analysis using the Blood-gas and Oximetry Linked Dataset (BOLD), analyzing critically ill patients from the eICU-CRD database (2014-2015). Patients with paired SpO<sub>2</sub>-SaO<sub>2</sub> measurements within five minutes were included. We identified SpO<sub>2</sub>-SaO<sub>2</sub> discrepancies as a difference of >2.99% and defined occult hypoxemia as an arterial partial pressure of oxygen (PaO<sub>2</sub>) < 60 mm Hg or SaO<sub>2</sub> < 89% with an SpO<sub>2</sub> > 88%. The primary outcomes included ICU length of stay (LOS), Sequential Organ Failure Assessment (SOFA) score, and in-hospital mortality.ResultsAmong 36,280 ICU patients, 23.6% had SpO<sub>2</sub>-SaO<sub>2</sub> discrepancies, and 4.7% had occult hypoxemia. Black patients were overrepresented in both groups, with an adjusted odds ratio (aOR) of 1.35 (95% CI: 1.25-1.47) for discrepancy and 1.22 (95% CI: 1.04-1.47) for occult hypoxemia. Higher BMI, lower pH, elevated creatinine, and higher Charlson Comorbidity Index scores were also significant predictors. Patients with discrepancies had worse clinical outcomes, including increased SOFA scores in the following 24 h (β = 0.31; <i>p</i> < .0001) and higher in-hospital mortality (aOR 1.15; <i>p</i> < .0001). Occult hypoxemia was associated with even worse outcomes, including a longer ICU LOS (IRR 1.12; <i>p</i> < .0001) and significantly increased mortality (aOR 1.73; <i>p</i> < .0001).InterpretationOne in four critically ill patient in our cohort experienced SpO<sub>2</sub>-SaO<sub>2</sub> discrepancy which is associated with adverse clinical outcomes. Black race, obesity, and higher comorbidity burden were significant predictors of these discrepancies. Our findings emphasize the need for more rigorous clinician oversight in the use of this technology.

Journal of Intensive Care MedicineVol. 40(12)
Thomas Jefferson University (US), Sidney Kimmel Cancer Center (US)
Good health and well-being
Openalex Percentile: Top 4%
Hemodynamic Monitoring and Therapy
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.