Signal properties study of neutron irradiated silicon photomultipliers down to 100 K

The LHCb experiment at CERN has been upgraded for the Run 3 operation of the Large Hadron Collider (LHC). A new concept of tracking detector based on Scintillating Fibres (SciFi) read out with multichannel silicon photomultipliers (SiPMs) was installed during its upgrade. One of the main challenges the SciFi tracker will face during its operation is the high radiation environment due to fast neutrons, where the SiPMs are located. In view of LHCb Upgrade II in 2033, the radiation levels will increase significantly, and the SciFi tracker must undergo a major upgrade. By the end of the lifetime, the expected radiation fluence will reach 3 . 0 × 1 0 12 n eq cm − 2 at the SiPMs’ location. To cope with the increase in radiation, cryogenic cooling with liquid nitrogen is being investigated as a possible solution to mitigate the performance degradation of the SiPMs induced by radiation damage. Thus, a detailed performance study of different layouts of SiPM modules produced by FBK and Hamamatsu is being carried out. These detectors have been designed to operate at cryogenic temperatures. Several detectors were irradiated with different neutron fluences and tested in a dedicated cryogenic setup down to 100 K. Key performance parameters, such as breakdown voltage, quenching resistor value, recovery time, and pulse amplitude, are characterized as a function of temperature and neutron fluence. Also, the forward voltage diode as a function of temperature was measured, and the silicon energy bandgap was estimated. The main results of this study are going to be presented here.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-07-16
DOI
https://doi.org/10.1016/j.nima.2025.170833
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Signal properties study of neutron irradiated silicon photomultipliers down to 100 K

F. Blanc, G. Haefeli, Gianluca Zunica, O. Schneider et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Radiation Detection and Scintillator Technologies
article

Signal properties study of neutron irradiated silicon photomultipliers down to 100 K

F. Blanc, G. Haefeli, Gianluca Zunica, O. Schneider, Esteban Currás Rivera, L. Shchutska, Federico Ronchetti, R. Marchevski
article en

Abstract

The LHCb experiment at CERN has been upgraded for the Run 3 operation of the Large Hadron Collider (LHC). A new concept of tracking detector based on Scintillating Fibres (SciFi) read out with multichannel silicon photomultipliers (SiPMs) was installed during its upgrade. One of the main challenges the SciFi tracker will face during its operation is the high radiation environment due to fast neutrons, where the SiPMs are located. In view of LHCb Upgrade II in 2033, the radiation levels will increase significantly, and the SciFi tracker must undergo a major upgrade. By the end of the lifetime, the expected radiation fluence will reach 3 . 0 × 1 0 12 n eq cm − 2 at the SiPMs’ location. To cope with the increase in radiation, cryogenic cooling with liquid nitrogen is being investigated as a possible solution to mitigate the performance degradation of the SiPMs induced by radiation damage. Thus, a detailed performance study of different layouts of SiPM modules produced by FBK and Hamamatsu is being carried out. These detectors have been designed to operate at cryogenic temperatures. Several detectors were irradiated with different neutron fluences and tested in a dedicated cryogenic setup down to 100 K. Key performance parameters, such as breakdown voltage, quenching resistor value, recovery time, and pulse amplitude, are characterized as a function of temperature and neutron fluence. Also, the forward voltage diode as a function of temperature was measured, and the silicon energy bandgap was estimated. The main results of this study are going to be presented here.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1081
École Polytechnique Fédérale de Lausanne (CH)
Affordable and clean energy
Openalex Percentile: Top 76%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.