3D printed microcyclones for enhanced collection, separation, and recovery of sub-micrometer bioaerosols

The collection and separation of aerosols is necessary to support the capture and analysis of particulate matter that can impact human health, enabling effective monitoring and prediction of exposure risk, and supporting fundamental studies of aerosol generation, transport, and distribution. Of particular concern are sub-micrometer particles which can deeply infiltrate the lungs, but efficient separation and capture of these smaller particles is challenging. In the case of bioaerosols, effective recovery of biological particles following capture often involves significant dilution of the collected sample, hindering downstream analysis. Here we report a miniature 3D printed cyclone-based platform capable of highly effective separation and recovery of submicron bioaerosols with well-defined cut-off sizes. Using a set of geometrically similar microcyclones fabricated at different size scales, with minimum channel dimensions of 0.75 mm, cut diameters as low as 0.05 μm are achieved at aerosol flow rates up to 5 L/min, with sharp cut-offs yielding nearly 100 % capture efficiency for larger particulates. Furthermore, captured influenza virus is recovered from the devices with up to 85 % efficiency and minimal dilution via a rapid elution process that takes advantage of the low internal microcyclone volume. The high capture efficiency for submicron particles enabled by the microcyclone platform, together with its compact form factor, effective sample recovery, tunable cut size, and cost-effective manufacture, makes the technology a promising tool for broad applications in aerosol and bioaerosol monitoring.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-07-16
DOI
https://doi.org/10.1016/j.snb.2025.138349
Citations
2
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D printed microcyclones for enhanced collection, separation, and recovery of sub-micrometer bioaerosols

Proma Bhattacharya, Sheldon Tai, Donald K. Milton, Akua Asa-Awuku et al.
2 citations
Sensors and Actuators B Chemical
Aerosol Filtration and Electrostatic Precipitation
1.46
article

3D printed microcyclones for enhanced collection, separation, and recovery of sub-micrometer bioaerosols

Proma Bhattacharya, Sheldon Tai, Donald K. Milton, Akua Asa-Awuku, Dewansh Rastogi, Don L. DeVoe, Alycia Smith, Atul Mehta, Juan Carlos de la Torre, Sima Mehraji, William C. Smith, Ali Hasani, Anna Pulley
article en
2 citations

Abstract

The collection and separation of aerosols is necessary to support the capture and analysis of particulate matter that can impact human health, enabling effective monitoring and prediction of exposure risk, and supporting fundamental studies of aerosol generation, transport, and distribution. Of particular concern are sub-micrometer particles which can deeply infiltrate the lungs, but efficient separation and capture of these smaller particles is challenging. In the case of bioaerosols, effective recovery of biological particles following capture often involves significant dilution of the collected sample, hindering downstream analysis. Here we report a miniature 3D printed cyclone-based platform capable of highly effective separation and recovery of submicron bioaerosols with well-defined cut-off sizes. Using a set of geometrically similar microcyclones fabricated at different size scales, with minimum channel dimensions of 0.75 mm, cut diameters as low as 0.05 μm are achieved at aerosol flow rates up to 5 L/min, with sharp cut-offs yielding nearly 100 % capture efficiency for larger particulates. Furthermore, captured influenza virus is recovered from the devices with up to 85 % efficiency and minimal dilution via a rapid elution process that takes advantage of the low internal microcyclone volume. The high capture efficiency for submicron particles enabled by the microcyclone platform, together with its compact form factor, effective sample recovery, tunable cut size, and cost-effective manufacture, makes the technology a promising tool for broad applications in aerosol and bioaerosol monitoring.

Sensors and Actuators B ChemicalVol. 444(Pt 1)
University of Maryland, College Park (US)
National Science Foundation, Division of Intramural Research, National Institute of Allergy and Infectious Diseases, National Institutes of Health
Openalex Percentile: Top 16%
Aerosol Filtration and Electrostatic Precipitation
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.