Evaluation of the operating parameters of a kinetic energy storage for the support of a generating set operating in island mode

The development of electric power systems is oriented toward increasing the share of electricity generated from renewable energy sources. These actions lead to the destabilization of the power grid, necessitating the implementation of stabilizing measures such as the temporary disconnection of renewable energy installations, the construction of energy storage systems, and the modernization of thermal energy sources. Modernization changes in electric power systems require significant financial investments and long implementation timelines. As a result, energy distributors are forced to make capital investments, which translate into high energy prices for consumers. For this reason, many companies, in optimizing the cost of their business operations, consider the possibility of operating within so- called isolated energy islands. Typically, this involves isolating the internal power network to supply a portion of the company’s production activities. This approach entails defining an internal power supply area and implementing an energy generation system in the form of a genset – a combustion engine combined with an electric generator. Such a system must ensure frequency stability within the isolated electrical network and provide the required amount of energy for the isolated system. These conditions can be met by a genset capable of generating approximately 150% of the energy demand. This leads to significantly increased investment costs and deteriorated operational conditions for the genset, resulting in reduced energy conversion efficiency.

Authors

Institutions

Publication Details

Journal
E3S Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/e3sconf/202563801003
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the operating parameters of a kinetic energy storage for the support of a generating set operating in island mode

Iliya Iliev, Paweł Imilkowski, Magdalena Dudek, K. Jesionek et al.
E3S Web of Conferences
Advanced Battery Technologies Research
article

Evaluation of the operating parameters of a kinetic energy storage for the support of a generating set operating in island mode

Iliya Iliev, Paweł Imilkowski, Magdalena Dudek, K. Jesionek, Jarosław Markowski, Grzegorz Wieczorkiewicz
article en

Abstract

The development of electric power systems is oriented toward increasing the share of electricity generated from renewable energy sources. These actions lead to the destabilization of the power grid, necessitating the implementation of stabilizing measures such as the temporary disconnection of renewable energy installations, the construction of energy storage systems, and the modernization of thermal energy sources. Modernization changes in electric power systems require significant financial investments and long implementation timelines. As a result, energy distributors are forced to make capital investments, which translate into high energy prices for consumers. For this reason, many companies, in optimizing the cost of their business operations, consider the possibility of operating within so- called isolated energy islands. Typically, this involves isolating the internal power network to supply a portion of the company’s production activities. This approach entails defining an internal power supply area and implementing an energy generation system in the form of a genset – a combustion engine combined with an electric generator. Such a system must ensure frequency stability within the isolated electrical network and provide the required amount of energy for the isolated system. These conditions can be met by a genset capable of generating approximately 150% of the energy demand. This leads to significantly increased investment costs and deteriorated operational conditions for the genset, resulting in reduced energy conversion efficiency.

E3S Web of ConferencesVol. 638
Witelon State University of Applied Sciences in Legnica (PL), DSW University of Lower Silesia (PL), Angel Kanchev University of Ruse (BG), Poznań University of Technology (PL), AGH University of Krakow (PL)
Openalex Percentile: Top 82%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.