Evaluation of Natural Lighting in the Lecture Room of the Graduate School of Syiah Kuala University

The Graduate School of Syiah Kuala University consists of five main buildings, one of which is Building B. Building B serves as a space for educational activities at the master's (S2) and doctoral (S3) levels. Based on observations, Building B features windows (openings) of very large dimensions, with the building and window orientations facing west and east. This condition results in excessive and glaring natural lighting, causing thermal discomfort. Consequently, the rooms are often used with curtains, artificial lighting such as lamps, and tinted glass windows, specifically ray-band glass. This study aims to evaluate the natural lighting levels in lecture rooms based on the Indonesian National Standard (SNI No. 6197-2020). Data collection was conducted using a quantitative method, obtained through direct visual observations and field measurements, including openings, building dimensions, and illumination levels measured with a Lux Meter. The measured illumination values were then analyzed based on the SNI No. 6197-2020 standard and the observational results, enabling the identification of factors affecting natural lighting intensity. The findings indicate that the natural lighting levels within the building do not meet the SNI 6197-2020 standard for classrooms, which is 350 Lux. The average illumination value measured using the Lux Meter was 109.69 Lux.

Authors

Publication Details

Journal
Review of Urbanism and Architectural Studies
Published
2025-06-06
DOI
https://doi.org/10.21776/ub.ruas.2025.023.01.6
Primary Topic
Architectural and Urban Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Natural Lighting in the Lecture Room of the Graduate School of Syiah Kuala University

Dinda Ramadani, Zahriah Zahriah, Riza Priandi
Review of Urbanism and Architectural Studies
Architectural and Urban Studies
article

Evaluation of Natural Lighting in the Lecture Room of the Graduate School of Syiah Kuala University

Dinda Ramadani, Zahriah Zahriah, Riza Priandi
article en

Abstract

The Graduate School of Syiah Kuala University consists of five main buildings, one of which is Building B. Building B serves as a space for educational activities at the master's (S2) and doctoral (S3) levels. Based on observations, Building B features windows (openings) of very large dimensions, with the building and window orientations facing west and east. This condition results in excessive and glaring natural lighting, causing thermal discomfort. Consequently, the rooms are often used with curtains, artificial lighting such as lamps, and tinted glass windows, specifically ray-band glass. This study aims to evaluate the natural lighting levels in lecture rooms based on the Indonesian National Standard (SNI No. 6197-2020). Data collection was conducted using a quantitative method, obtained through direct visual observations and field measurements, including openings, building dimensions, and illumination levels measured with a Lux Meter. The measured illumination values were then analyzed based on the SNI No. 6197-2020 standard and the observational results, enabling the identification of factors affecting natural lighting intensity. The findings indicate that the natural lighting levels within the building do not meet the SNI 6197-2020 standard for classrooms, which is 350 Lux. The average illumination value measured using the Lux Meter was 109.69 Lux.

Review of Urbanism and Architectural StudiesVol. 23(1)
Openalex Percentile: Top 78%
Architectural and Urban Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.