Assessment of IoT low-cost sensor networks for long-term outdoor and indoor air quality monitoring: a case study in Dublin

This study provides a framework for Internet of Things based low-cost sensors (LCS) network implementation, using office environments in Dublin, Ireland, as a case study for long-term indoor air quality (IAQ) monitoring. It covers options and key decisions related to sensor technology, reporting systems and data management. Environmental and indoor data were collected from 1 June 2023 to 20 June 2024, using Smart Citizen Kit 2.1 and PurpleAir devices, and data retrieved from cloud-based data platforms for analysis. The standard deviation and coefficient of variation were calculated to evaluate intra-sensor precision. To improve data quality of LCS various correction models were tested, considering the impact of temperature and relative humidity. A multilinear model with additive relative humidity, using the piecewise regression, provided better performance (R 2 > 0.7, RMSE < 5 μg/m 3 ) and accuracy (> 0.88) for 24-h fine particulate matter (PM 2.5 ) and respiratory particulate matter (PM 10 ). This study bridges the data gap by incorporating multi-brand LCS network for further application in outdoor supplementary and IAQ reporting. The results showed corrected indoor PM 2.5 data in offices complies with WHO air quality guidelines, and carbon dioxide (CO 2 ) levels in naturally ventilated conditions remained below 800 ppm. Additionally, diurnal patterns reveal elevated levels of CO 2 and total volatile organic compounds during core office hours, while the contrasting patterns for PM 2.5 suggest outdoor infiltration as the dominant source. This study demonstrates the potential of data-driven techniques for real-time IAQ monitoring and reporting, providing valuable insights for promoting healthier IAQ for occupants. • Implementation of an IoT based low-cost sensors system for long-term IAQ monitoring • Key decisions regarding IoT low-cost sensor network deployment • Challenges related to intra-sensor percision and sensor to reference accuracy • Relative humidity plays a major role in long-lasting PM sensor performance • Calibration models and correction equations enhance accuracy of PM reporting

Authors

Institutions

Publication Details

Journal
Atmospheric Pollution Research
Published
2025-07-16
DOI
https://doi.org/10.1016/j.apr.2025.102651
Citations
1
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of IoT low-cost sensor networks for long-term outdoor and indoor air quality monitoring: a case study in Dublin

Óscar González, David H. O’Connor, Lindsay A. Tallon, Francesco Pilla et al.
1 citations
Atmospheric Pollution Research
Air Quality Monitoring and Forecasting
0.80
article

Assessment of IoT low-cost sensor networks for long-term outdoor and indoor air quality monitoring: a case study in Dublin

Óscar González, David H. O’Connor, Lindsay A. Tallon, Francesco Pilla, Xiaocui Chen
article en
1 citations

Abstract

This study provides a framework for Internet of Things based low-cost sensors (LCS) network implementation, using office environments in Dublin, Ireland, as a case study for long-term indoor air quality (IAQ) monitoring. It covers options and key decisions related to sensor technology, reporting systems and data management. Environmental and indoor data were collected from 1 June 2023 to 20 June 2024, using Smart Citizen Kit 2.1 and PurpleAir devices, and data retrieved from cloud-based data platforms for analysis. The standard deviation and coefficient of variation were calculated to evaluate intra-sensor precision. To improve data quality of LCS various correction models were tested, considering the impact of temperature and relative humidity. A multilinear model with additive relative humidity, using the piecewise regression, provided better performance (R 2 > 0.7, RMSE < 5 μg/m 3 ) and accuracy (> 0.88) for 24-h fine particulate matter (PM 2.5 ) and respiratory particulate matter (PM 10 ). This study bridges the data gap by incorporating multi-brand LCS network for further application in outdoor supplementary and IAQ reporting. The results showed corrected indoor PM 2.5 data in offices complies with WHO air quality guidelines, and carbon dioxide (CO 2 ) levels in naturally ventilated conditions remained below 800 ppm. Additionally, diurnal patterns reveal elevated levels of CO 2 and total volatile organic compounds during core office hours, while the contrasting patterns for PM 2.5 suggest outdoor infiltration as the dominant source. This study demonstrates the potential of data-driven techniques for real-time IAQ monitoring and reporting, providing valuable insights for promoting healthier IAQ for occupants. • Implementation of an IoT based low-cost sensors system for long-term IAQ monitoring • Key decisions regarding IoT low-cost sensor network deployment • Challenges related to intra-sensor percision and sensor to reference accuracy • Relative humidity plays a major role in long-lasting PM sensor performance • Calibration models and correction equations enhance accuracy of PM reporting

Atmospheric Pollution ResearchVol. 16(11)
University College Dublin (IE), Massachusetts College of Pharmacy and Health Sciences (US), Institute for Advanced Architecture of Catalonia (ES)
Openalex Percentile: Top 27%
Air Quality Monitoring and Forecasting
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.