Development and performance evaluation of portable thyroid monitor for <i>in vivo</i> monitoring of 131I

A compact, portable, and tabletop thyroid monitor has been developed for in vivo measurement of 131I activity in the thyroid. This system is designed for use in laboratory settings for monitoring of occupational workers and is also suitable for onsite deployment by radiological emergency response teams during radiation emergency situations for thyroidal measurement of the general public. The monitor incorporates a 51 mm diameter × 51 mm-thick NaI(Tl) scintillation detector coupled with a standalone 1 K multi-channel analyzer, housed within a shielded collimator. The system allows for variable counting geometries, accommodating diverse measurement requirements. Key design elements include a vertical movement system, a chin rest, a calibrated neck-to-collimator distance scale, and an Light Emitting Diode-based alignment indicator to ensure precise positioning of the thyroid relative to the detector. A specialized software has been developed for the quantification of thyroidal 131I activity, intake estimation, and committed effective dose calculation. Under normal radiation background conditions (~70 nSv/h), the system achieves a minimum detectable activity of 60 Bq with a 5-min counting time. The monitor is capable of accurately assessing thyroid equivalent doses below 50 mSv, even under conditions of elevated environmental radiation following radiation emergency situations. This system enhances rapid and in situ thyroidal 131I monitoring, supporting radiation protection efforts in both routine monitoring and emergency response scenarios.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-06-30
DOI
https://doi.org/10.1093/rpd/ncaf084
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and performance evaluation of portable thyroid monitor for in vivo monitoring of 131I

Pramilla D. Sawant, M S Kulkarni, Pradeep Prathibha, Probal Chaudhury et al.
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Development and performance evaluation of portable thyroid monitor for in vivo monitoring of 131I

Pramilla D. Sawant, M S Kulkarni, Pradeep Prathibha, Probal Chaudhury, Rajesh Sankhla
article en

Abstract

A compact, portable, and tabletop thyroid monitor has been developed for in vivo measurement of 131I activity in the thyroid. This system is designed for use in laboratory settings for monitoring of occupational workers and is also suitable for onsite deployment by radiological emergency response teams during radiation emergency situations for thyroidal measurement of the general public. The monitor incorporates a 51 mm diameter × 51 mm-thick NaI(Tl) scintillation detector coupled with a standalone 1 K multi-channel analyzer, housed within a shielded collimator. The system allows for variable counting geometries, accommodating diverse measurement requirements. Key design elements include a vertical movement system, a chin rest, a calibrated neck-to-collimator distance scale, and an Light Emitting Diode-based alignment indicator to ensure precise positioning of the thyroid relative to the detector. A specialized software has been developed for the quantification of thyroidal 131I activity, intake estimation, and committed effective dose calculation. Under normal radiation background conditions (~70 nSv/h), the system achieves a minimum detectable activity of 60 Bq with a 5-min counting time. The monitor is capable of accurately assessing thyroid equivalent doses below 50 mSv, even under conditions of elevated environmental radiation following radiation emergency situations. This system enhances rapid and in situ thyroidal 131I monitoring, supporting radiation protection efforts in both routine monitoring and emergency response scenarios.

Radiation Protection DosimetryVol. 201(11)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN)
Openalex Percentile: Top 75%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and performance evaluation of portable thyroid monitor for <i>in vivo</i> monitoring of 131I — Pramilla D. Sawant, M S Kulkarni, et al. · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS