Experimental Validation of Collision Safety in Prismatic Joints Using Magnetic Coupling

This study presents a prismatic joint structure that utilizes magnetic coupling to enhance safety during collisions. Conventional prismatic joints using electric motors typically involve components such as gearboxes and rigid couplings. In contrast, the proposed design features permanent magnets arranged on the motor output shaft and the gearbox input shaft, enabling non-contact power transfer through an axial magnetic coupling mechanism. The proposed design prevents overload by utilizing the decoupling of the magnetic coupling in the event of a collision. This results in improved safety of mechanical components during impact situations compared to conventional designs. Prior to experimentation, magnetic film was employed to verify the magnet arrangement, and the transmitted torque via the distance between magnet array was experimentally determined. The experiment compared the motor speed, q-axis current, and the load applied to the impact surface during the collision process, based on the presence or absence of magnetic coupling. Experimental findings confirmed the proposed effect provided by the magnetic coupling.

Authors

Institutions

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1109/iccar64901.2025.11073046
Citations
1
Primary Topic
Magnetic Bearings and Levitation Dynamics
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Validation of Collision Safety in Prismatic Joints Using Magnetic Coupling

HyoJae Kang, Min-Sung Kang
1 citations
Magnetic Bearings and Levitation Dynamics
1.21
article

Experimental Validation of Collision Safety in Prismatic Joints Using Magnetic Coupling

HyoJae Kang, Min-Sung Kang
article en
1 citations

Abstract

This study presents a prismatic joint structure that utilizes magnetic coupling to enhance safety during collisions. Conventional prismatic joints using electric motors typically involve components such as gearboxes and rigid couplings. In contrast, the proposed design features permanent magnets arranged on the motor output shaft and the gearbox input shaft, enabling non-contact power transfer through an axial magnetic coupling mechanism. The proposed design prevents overload by utilizing the decoupling of the magnetic coupling in the event of a collision. This results in improved safety of mechanical components during impact situations compared to conventional designs. Prior to experimentation, magnetic film was employed to verify the magnet arrangement, and the transmitted torque via the distance between magnet array was experimentally determined. The experiment compared the motor speed, q-axis current, and the load applied to the impact surface during the collision process, based on the presence or absence of magnetic coupling. Experimental findings confirmed the proposed effect provided by the magnetic coupling.

Hanyang University (KR), Anyang University (KR)
Openalex Percentile: Top 19%
Magnetic Bearings and Levitation Dynamics
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Validation of Collision Safety in Prismatic Joints Using Magnetic Coupling — HyoJae Kang, Min-Sung Kang · (2025) | TGRS Research Map | TGRS