LNFM: High-Precision Frequency Stability Measurement System of Atomic Oscillators With Built-In Reference Source

Precise frequency stability measurement is critical for many advanced applications, including satellite navigation and remote communication. Traditional measurement systems rely on external high-precision reference sources such as hydrogen maser (HM), cesium (Cs) atomic clock which are costly, bulky, and challenging to deploy in remote or mobile scenarios. To address these limitations, this work develops a compact and cost-effective low noise frequency stability measurement system (LNFM). The system uses precise point timing (PPT) technology to dynamically adjust oven-controlled crystal oscillators (OCXO). This approach compensates for long-term frequency drift and enables the OCXO to serve as a stable internal reference (REF) with a frequency stability of 1.0 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">’14</sup>@10, 000 s. This capability allows LNFM to function as a standalone device for frequency stability measurement. Besides, to reduce design complexity and cost, LNFM adopts a software-defined radio (SDR)-based dual-mixer time difference (DMTD) method, achieving a noise floor level of 5.3 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-14</sup>τ<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>. Furthermore, this paper presents an Analog-to-Digital Converter (ADC) phase distortion model to analyze the theoretical noise floor bound introduced by the ADC in the LNFM system. The proposed system provides an accessible alternative for applications where external REF are impractical. To validate the system, a rubidium (Rb) clock is measured and evaluated. The results show that its ADEV measurement precision is comparable to commercial instruments with HM as REF at τ > 1000s. This system provides a portable and reliable solution for modern frequency stability measurement.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3588945
Citations
1
Primary Topic
Advanced Frequency and Time Standards
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LNFM: High-Precision Frequency Stability Measurement System of Atomic Oscillators With Built-In Reference Source

Liangcheng Deng, Biao Fu, Fu Zheng, Dong Zhang et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Advanced Frequency and Time Standards
1.25
article

LNFM: High-Precision Frequency Stability Measurement System of Atomic Oscillators With Built-In Reference Source

Liangcheng Deng, Biao Fu, Fu Zheng, Dong Zhang, Chuang Shi, Yu Xue
article en
1 citations

Abstract

Precise frequency stability measurement is critical for many advanced applications, including satellite navigation and remote communication. Traditional measurement systems rely on external high-precision reference sources such as hydrogen maser (HM), cesium (Cs) atomic clock which are costly, bulky, and challenging to deploy in remote or mobile scenarios. To address these limitations, this work develops a compact and cost-effective low noise frequency stability measurement system (LNFM). The system uses precise point timing (PPT) technology to dynamically adjust oven-controlled crystal oscillators (OCXO). This approach compensates for long-term frequency drift and enables the OCXO to serve as a stable internal reference (REF) with a frequency stability of 1.0 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">’14</sup>@10, 000 s. This capability allows LNFM to function as a standalone device for frequency stability measurement. Besides, to reduce design complexity and cost, LNFM adopts a software-defined radio (SDR)-based dual-mixer time difference (DMTD) method, achieving a noise floor level of 5.3 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-14</sup>τ<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>. Furthermore, this paper presents an Analog-to-Digital Converter (ADC) phase distortion model to analyze the theoretical noise floor bound introduced by the ADC in the LNFM system. The proposed system provides an accessible alternative for applications where external REF are impractical. To validate the system, a rubidium (Rb) clock is measured and evaluated. The results show that its ADEV measurement precision is comparable to commercial instruments with HM as REF at τ > 1000s. This system provides a portable and reliable solution for modern frequency stability measurement.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Beihang University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 19%
Advanced Frequency and Time Standards
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.