Design and Implementation of Active Control Method for Minimizing Circulating Current in MMC-VSC System

Modular Multilevel Converters (MMCs) have emerged as a key technology for large-scale renewable energy integration due to their scalability, fault tolerance, and superior output quality. However, internal circulating currents remain a major barrier to efficiency and long-term reliability. It causes power losses, increased thermal stress, and excessive capacitor voltage fluctuations. Existing passive and active methods often lack clear design guidelines or fail to achieve robust suppression under varying operating conditions. This paper introduces a comprehensive hybrid strategy that addresses these gaps through two key innovations. Firstly, an analytical expression for arm inductor sizing is derived using instantaneous power theory and the harmonic addition theorem. It offers an explicit passive design method rather than relying on heuristic selection. This analytical formulation ensures optimal passive suppression within practical inductor size constraints.Then an advanced active suppression scheme is developed. Unlike conventional approaches, the circulating current is regulated using a vector control strategy formulated in the dq reference frame. It enables precise control of the dominant second-order harmonic. The PI controller is tuned through a direct pole placement method. A high-pass filter is integrated upstream of the controller to eliminate the DC offset. The simulation studies demonstrates that the proposed methods outperforms traditional direct modulation by significantly reducing circulating current amplitude, lowering power losses and improving thermal performance. The results confirm that the passive and active control framework delivers a robust, scalable, and practically implementable solution for next-generation MMC-based renewable energy systems.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3588713
Citations
4
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
2.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Implementation of Active Control Method for Minimizing Circulating Current in MMC-VSC System

Muhammad Raza, Amna Aslam
4 citations
IEEE Access
HVDC Systems and Fault Protection
2.92
article

Design and Implementation of Active Control Method for Minimizing Circulating Current in MMC-VSC System

Muhammad Raza, Amna Aslam
article en
4 citations

Abstract

Modular Multilevel Converters (MMCs) have emerged as a key technology for large-scale renewable energy integration due to their scalability, fault tolerance, and superior output quality. However, internal circulating currents remain a major barrier to efficiency and long-term reliability. It causes power losses, increased thermal stress, and excessive capacitor voltage fluctuations. Existing passive and active methods often lack clear design guidelines or fail to achieve robust suppression under varying operating conditions. This paper introduces a comprehensive hybrid strategy that addresses these gaps through two key innovations. Firstly, an analytical expression for arm inductor sizing is derived using instantaneous power theory and the harmonic addition theorem. It offers an explicit passive design method rather than relying on heuristic selection. This analytical formulation ensures optimal passive suppression within practical inductor size constraints.Then an advanced active suppression scheme is developed. Unlike conventional approaches, the circulating current is regulated using a vector control strategy formulated in the dq reference frame. It enables precise control of the dominant second-order harmonic. The PI controller is tuned through a direct pole placement method. A high-pass filter is integrated upstream of the controller to eliminate the DC offset. The simulation studies demonstrates that the proposed methods outperforms traditional direct modulation by significantly reducing circulating current amplitude, lowering power losses and improving thermal performance. The results confirm that the passive and active control framework delivers a robust, scalable, and practically implementable solution for next-generation MMC-based renewable energy systems.

IEEE AccessVol. 13
Bahria University (PK)
Higher Education Commission, Pakistan
Openalex Percentile: Top 9%
HVDC Systems and Fault Protection
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Implementation of Active Control Method for Minimizing Circulating Current in MMC-VSC System — Muhammad Raza, Amna Aslam · IEEE Access (2025) | TGRS Research Map | TGRS