Fault Detection Technique for Active Phased Array Antenna Using Current Sensing

This article presents the design and implementation of a built-in fault detection technique for an active phased array antenna. The proposed method employs a current monitoring circuit integrated into the power protection board of the transmit-receive unit (TRU). This circuit consists of a current sense amplifier and an operational amplifier, which detect the drain current of the high-power amplifier within the transmit-receive module (TRM) and compare it against a predefined detection threshold. To facilitate channel control and status reporting of individual TRMs, a built-in test function was implemented in the field-programmable gate array within both the antenna controller and the TRU control board. The test logic monitors the pulse output of the current monitoring circuit and requires four pulse transmissions to confirm a fault. The effectiveness of the proposed technique was evaluated through an initial test using a TRU with an intentionally damaged TRM. Further validation was conducted at both the antenna and radar system levels. The results demonstrated that the antenna can accurately detect and isolate failed TRMs, thereby confirming the reliability of the proposed fault detection method.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3589236
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Detection Technique for Active Phased Array Antenna Using Current Sensing

Hongjoon Kim, Shin Young Cho, Seung-Hee Seo, Hongwoo Park et al.
IEEE Access
Electrical Fault Detection and Protection
article

Fault Detection Technique for Active Phased Array Antenna Using Current Sensing

Hongjoon Kim, Shin Young Cho, Seung-Hee Seo, Hongwoo Park, Won Jin Lee
article en

Abstract

This article presents the design and implementation of a built-in fault detection technique for an active phased array antenna. The proposed method employs a current monitoring circuit integrated into the power protection board of the transmit-receive unit (TRU). This circuit consists of a current sense amplifier and an operational amplifier, which detect the drain current of the high-power amplifier within the transmit-receive module (TRM) and compare it against a predefined detection threshold. To facilitate channel control and status reporting of individual TRMs, a built-in test function was implemented in the field-programmable gate array within both the antenna controller and the TRU control board. The test logic monitors the pulse output of the current monitoring circuit and requires four pulse transmissions to confirm a fault. The effectiveness of the proposed technique was evaluated through an initial test using a TRU with an intentionally damaged TRM. Further validation was conducted at both the antenna and radar system levels. The results demonstrated that the antenna can accurately detect and isolate failed TRMs, thereby confirming the reliability of the proposed fault detection method.

IEEE AccessVol. 13
Agency for Defense Development (KR), Kyungpook National University (KR)
Agency for Defense Development
Affordable and clean energy
Openalex Percentile: Top 85%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.