The Anti-Nucleocapsid IgG Antibody as a Marker of SARS-CoV-2 Infection for Hemodialysis Patients

<i><b>Background:</b></i> Hemodialysis patients, due to impaired kidney function and compromised immune responses, face increased risks from SARS-CoV-2. Anti-nucleocapsid IgG (anti-IgG N) antibodies are a commonly used marker to assess prior infection in the general population; however, their efficacy for hemodialysis patients remains unclear. <i><b>Methods:</b></i> A retrospective study of 361 hemodialysis patients evaluated anti-IgG N antibodies for detecting prior SARS-CoV-2 infection. Antibody levels were measured using a chemiluminescence immunoassay (CLIA) over the four time points. Boxplots illustrated antibody distribution across sampling stages and infection status. Logistic regression and receiver operating characteristic (ROC) curve analysis determined diagnostic accuracy, sensitivity, specificity, and optimal cutoff values. <i><b>Results:</b></i> Among the 361 hemodialysis patients, 36 (10.0%) had SARS-CoV-2 infection. Sex distribution showed a trend toward significance (<i>p</i> = 0.05). Boxplot analysis showed that anti-IgG N levels remained low in non-infected patients but increased in infected patients, peaking at the third sampling. Anti-IgG N demonstrated high diagnostic accuracy (AUC: 0.973-0.865) but declined over time (<i>p</i> = 0.00525). The optimal cutoff at C1 was 0.01 AU/mL (sensitivity 1.00, specificity 0.94). Adjusted models had lower predictive value. <i><b>Conclusions:</b></i> Anti-IgG N antibodies showed high diagnostic accuracy for detecting prior SARS-CoV-2 infection in hemodialysis patients, though performance declined over time. These findings highlight the need for tailored diagnostic strategies in this vulnerable population.

Authors

Institutions

Publication Details

Journal
Vaccines
Published
2025-07-13
DOI
https://doi.org/10.3390/vaccines13070750
Primary Topic
SARS-CoV-2 and COVID-19 Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Anti-Nucleocapsid IgG Antibody as a Marker of SARS-CoV-2 Infection for Hemodialysis Patients

Akihiko Ozaki, Yurie Kobashi, Tianchen Zhao, Chika Yamamoto et al.
Vaccines
SARS-CoV-2 and COVID-19 Research
article

The Anti-Nucleocapsid IgG Antibody as a Marker of SARS-CoV-2 Infection for Hemodialysis Patients

Akihiko Ozaki, Yurie Kobashi, Tianchen Zhao, Chika Yamamoto, Takeshi Kawamura, Masatoshi Wakui, Yudai Kaneko, Akira Sugiyama, Hiroaki Saito, Masaharu Tsubokura, Toyoaki Sawano, Toshiki Abe, Yuki Sonoda, Shun Watanabe, Hiroaki Shimmura, Aya Nakayama, A Hara
article en

Abstract

<i><b>Background:</b></i> Hemodialysis patients, due to impaired kidney function and compromised immune responses, face increased risks from SARS-CoV-2. Anti-nucleocapsid IgG (anti-IgG N) antibodies are a commonly used marker to assess prior infection in the general population; however, their efficacy for hemodialysis patients remains unclear. <i><b>Methods:</b></i> A retrospective study of 361 hemodialysis patients evaluated anti-IgG N antibodies for detecting prior SARS-CoV-2 infection. Antibody levels were measured using a chemiluminescence immunoassay (CLIA) over the four time points. Boxplots illustrated antibody distribution across sampling stages and infection status. Logistic regression and receiver operating characteristic (ROC) curve analysis determined diagnostic accuracy, sensitivity, specificity, and optimal cutoff values. <i><b>Results:</b></i> Among the 361 hemodialysis patients, 36 (10.0%) had SARS-CoV-2 infection. Sex distribution showed a trend toward significance (<i>p</i> = 0.05). Boxplot analysis showed that anti-IgG N levels remained low in non-infected patients but increased in infected patients, peaking at the third sampling. Anti-IgG N demonstrated high diagnostic accuracy (AUC: 0.973-0.865) but declined over time (<i>p</i> = 0.00525). The optimal cutoff at C1 was 0.01 AU/mL (sensitivity 1.00, specificity 0.94). Adjusted models had lower predictive value. <i><b>Conclusions:</b></i> Anti-IgG N antibodies showed high diagnostic accuracy for detecting prior SARS-CoV-2 infection in hemodialysis patients, though performance declined over time. These findings highlight the need for tailored diagnostic strategies in this vulnerable population.

VaccinesVol. 13(7)
Tokyo Institute of Technology (JP), Fukushima Medical University (JP), Keio University (JP), Jyoban Hospital of Tokiwa Foundation (JP), Medical & Biological Laboratories (Japan) (JP), Soma Central Hospital (JP), The University of Tokyo (JP), Murata (Japan) (JP)
Japan Agency for Medical Research and Development, Moderna
Openalex Percentile: Top 79%
SARS-CoV-2 and COVID-19 Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.