Experimental Study on Shear Performance of High⁃Strength Bolt Efficient Connections at Elevated Temperatures

To investigate the shear-bearing capacity of high-strength bolt efficient connections with high slip-resistant coefficients under elevated temperatures, tensile tests were first conducted on Q355 and Q960 base material specimens (matching the connection components) and Grade 8.8 bolt material specimens under both ambient and high-temperature conditions. This established the temperature-dependent relationships for elastic modulus, yield strength, and tensile strength of the materials. Subsequently, high-temperature shear performance tests were performed on eight high-strength bolt efficient connections to examine the effects of different temperatures and hole configurations on failure modes, slip loads, and ultimate loads. The results demonstrate that: the failure mode of high-strength bolt efficient connections transitions from net-section failure to bolt shear failure within the 300-400°C temperature range; both slip load and ultimate load decrease with increasing temperature, showing 75% and 51% reductions respectively at 500°C compared to ambient conditions for standard hole specimens; different hole configurations exhibit limited influence on the ultimate shear capacity of connections at 500 °C.

Authors

Publication Details

Journal
Industrial Construction
Published
2025-05-01
DOI
https://doi.org/10.3724/j.gyjzg24072209
Primary Topic
Tree Root and Stability Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on Shear Performance of High⁃Strength Bolt Efficient Connections at Elevated Temperatures

Lin Ma, Zhenming CHEN, Fei Gao, Zongyi Wang
Industrial Construction
Tree Root and Stability Studies
article

Experimental Study on Shear Performance of High⁃Strength Bolt Efficient Connections at Elevated Temperatures

Lin Ma, Zhenming CHEN, Fei Gao, Zongyi Wang
article en

Abstract

To investigate the shear-bearing capacity of high-strength bolt efficient connections with high slip-resistant coefficients under elevated temperatures, tensile tests were first conducted on Q355 and Q960 base material specimens (matching the connection components) and Grade 8.8 bolt material specimens under both ambient and high-temperature conditions. This established the temperature-dependent relationships for elastic modulus, yield strength, and tensile strength of the materials. Subsequently, high-temperature shear performance tests were performed on eight high-strength bolt efficient connections to examine the effects of different temperatures and hole configurations on failure modes, slip loads, and ultimate loads. The results demonstrate that: the failure mode of high-strength bolt efficient connections transitions from net-section failure to bolt shear failure within the 300-400°C temperature range; both slip load and ultimate load decrease with increasing temperature, showing 75% and 51% reductions respectively at 500°C compared to ambient conditions for standard hole specimens; different hole configurations exhibit limited influence on the ultimate shear capacity of connections at 500 °C.

Industrial ConstructionVol. 55(5)
Affordable and clean energy
Openalex Percentile: Top 83%
Tree Root and Stability Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Study on Shear Performance of High⁃Strength Bolt Efficient Connections at Elevated Temperatures — Lin Ma, Zhenming CHEN, et al. · Industrial Construction (2025) | TGRS Research Map | TGRS