A portable smartphone-based electrochemical sensing platform for rapid and sensitive detection of creatinine in blood serum

Muscle metabolism produces creatinine, a waste product whose levels in the blood and urine are crucial markers of kidney health. Herein, a smartphone-based electrochemical detection strategy was developed to quantify creatinine in human blood serum. Since creatinine was electrochemically inactive, a standard copper solution was added as an electro-activator to produce an electrochemically active creatinine-copper complex. At a pH of 7.4, the creatinine-copper composite was oxidized in a phosphate buffer solution (PBS). Electrochemical oxidation of the free Cu<sup>+</sup> ion in PBS is tested by the surface modification of Ti<sub>2</sub>C<sub>2</sub>T <sub><i>x</i></sub> @poly(l-Arg) nanocomposite. The analytical performance of the developed electrochemical sensor was evaluated by differential pulse voltammetry. The developed electrochemical sensor was evaluated using a combination of techniques: electrochemical methods like cyclic voltammetry and electrochemical impedance spectroscopy, morphological analysis with scanning electron microscopy, and structural analysis with attenuated total reflectance Fourier transform infrared spectroscopy and X-ray diffraction. Notably, the developed sensor demonstrated an impressively low detection limit of 0.05 μM and a linear range of 1-200 μM. Moreover, the sensor remarkably exhibited a stable creatinine detection response with an acceptable reproducibility for two two-week periods and demonstrated a robust immunity against interfering molecules. This is the first report on the synthesis of Ti<sub>2</sub>C<sub>2</sub>T <sub><i>x</i></sub> @poly(l-Arg) nanocomposites and their application in the electrochemical detection of creatinine. This smartphone-based creatinine sensor offers a promising, rapid, and reliable technique for creatinine detection, with potential applications in clinical diagnostics and biomedical research, due to its high sensitivity, selectivity, and portability.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ra03128a
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A portable smartphone-based electrochemical sensing platform for rapid and sensitive detection of creatinine in blood serum

Md. Abdul Khaleque, Md. Romzan Ali, MA Zaed, K.H. Tan et al.
4 citations
RSC Advances
Electrochemical sensors and biosensors
2.92
article

A portable smartphone-based electrochemical sensing platform for rapid and sensitive detection of creatinine in blood serum

Md. Abdul Khaleque, Md. Romzan Ali, MA Zaed, K.H. Tan, Mohamed Aly Saad Aly, Md. Ruhul Amin, R. Saidur, Md. Zaved Hossain Khan, Shakib Mahmud Ayon, Rifat Rayhan, Md. Inzamamul Haque Shishir
article en
4 citations

Abstract

Muscle metabolism produces creatinine, a waste product whose levels in the blood and urine are crucial markers of kidney health. Herein, a smartphone-based electrochemical detection strategy was developed to quantify creatinine in human blood serum. Since creatinine was electrochemically inactive, a standard copper solution was added as an electro-activator to produce an electrochemically active creatinine-copper complex. At a pH of 7.4, the creatinine-copper composite was oxidized in a phosphate buffer solution (PBS). Electrochemical oxidation of the free Cu<sup>+</sup> ion in PBS is tested by the surface modification of Ti<sub>2</sub>C<sub>2</sub>T <sub><i>x</i></sub> @poly(l-Arg) nanocomposite. The analytical performance of the developed electrochemical sensor was evaluated by differential pulse voltammetry. The developed electrochemical sensor was evaluated using a combination of techniques: electrochemical methods like cyclic voltammetry and electrochemical impedance spectroscopy, morphological analysis with scanning electron microscopy, and structural analysis with attenuated total reflectance Fourier transform infrared spectroscopy and X-ray diffraction. Notably, the developed sensor demonstrated an impressively low detection limit of 0.05 μM and a linear range of 1-200 μM. Moreover, the sensor remarkably exhibited a stable creatinine detection response with an acceptable reproducibility for two two-week periods and demonstrated a robust immunity against interfering molecules. This is the first report on the synthesis of Ti<sub>2</sub>C<sub>2</sub>T <sub><i>x</i></sub> @poly(l-Arg) nanocomposites and their application in the electrochemical detection of creatinine. This smartphone-based creatinine sensor offers a promising, rapid, and reliable technique for creatinine detection, with potential applications in clinical diagnostics and biomedical research, due to its high sensitivity, selectivity, and portability.

RSC AdvancesVol. 15(30)
Georgia Institute of Technology (US), Lancaster University (GB), Sunway University (MY)
Responsible consumption and production
Openalex Percentile: Top 9%
Electrochemical sensors and biosensors
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.