No More Feet-first Supine: A Simplified Total Body Irradiation Planning and Delivery Using Single Head-first Supine CT Simulation and SGRT for Intra-fraction Motion Monitoring on Radixact Tomotherapy

<i>Introduction</i>: Total Body Irradiation (TBI) remains a crucial preparatory regimen for hematopoietic stem cell transplantation. However, traditional techniques involve complex workflows requiring dual CT simulations-Head-First Supine (HFS) and Feet-First Supine (FFS)-which pose logistical, dosimetric, and patient comfort challenges. This study introduces a simplified TBI approach using a single HFS CT scan combined with Surface Guided Radiation Therapy (SGRT) for setup verification and intra-fraction motion monitoring on the Radixact® TomoTherapy system. <i>Materials and Methods</i>: From August 2024 to April 2025, five adult patients with hematologic malignancies scheduled for TBI were retrospectively analyzed. Each patient underwent a single HFS simulation scan on PET-CT with full-body coverage. Immobilization was achieved using a vacuum cushion and thermoplastic mask. Treatment planning was performed using Accuray Precision® version 3.5.0.2 on a single CT dataset. Two helical plans, one for the upper body and one for the lower body, were generated with a 14 cm overlap at the mid-thigh. Seven feathered Planning Target Volumes (PTVs) were created at the junction to ensure dose homogeneity. Surface Guided Radiation Therapy (SGRT) was used for initial setup and intra-fraction motion monitoring, while ClearRT-based kVCT imaging served as a secondary internal verification. Patient-specific quality assurance (PSQA) was conducted using Delta4 with 3%/3 mm gamma criteria, and junction dose validation was performed using ion chamber measurements. <i>Results</i>: SGRT enabled accurate patient setup for TBI, with mean translational errors ≤2 mm and rotational errors ≤0.6° when compared to kVCT verification. Real-time motion monitoring during treatment enabled automatic beam-holds with an average latency of 0.0038 seconds, ensuring precise delivery. Dosimetric results showed excellent target coverage (≥95% of the PTV receiving ≥95% of the prescribed dose) and homogeneous dose distribution. Smooth dose profiles were observed at plan junctions, and lung doses remained within safe limits (~1.7 Gy). Pre-treatment QA demonstrated high gamma pass rates across all body regions (mean ≥96.6%), confirming treatment accuracy. <i>Discussion</i>: This simple modified workflow utilizing a single HFS CT scan for full-body TBI on Radixact eliminates the need for patient repositioning and FFS imaging, thereby simplifying the planning and delivery process. Integration of SGRT provides non-ionizing, real-time monitoring, enhancing setup precision and intra-fraction control. The feathered PTV junction design effectively mitigated dose inhomogeneities. This method demonstrates not only dosimetric robustness but also improved workflow efficiency and patient comfort.

Authors

Institutions

Publication Details

Journal
International Journal of Clinical Oncology and Cancer Research
Published
2025-07-04
DOI
https://doi.org/10.11648/j.ijcocr.20251003.11
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

No More Feet-first Supine: A Simplified Total Body Irradiation Planning and Delivery Using Single Head-first Supine CT Simulation and SGRT for Intra-fraction Motion Monitoring on Radixact Tomotherapy

Amit Nirhali, R. S. Pagare, Sanjay Hunugundmath, M. Deputy et al.
International Journal of Clinical Oncology and Cancer Research
Advanced Radiotherapy Techniques
article

No More Feet-first Supine: A Simplified Total Body Irradiation Planning and Delivery Using Single Head-first Supine CT Simulation and SGRT for Intra-fraction Motion Monitoring on Radixact Tomotherapy

Amit Nirhali, R. S. Pagare, Sanjay Hunugundmath, M. Deputy, Sharad Gadhave, Vishram Naik
article en

Abstract

<i>Introduction</i>: Total Body Irradiation (TBI) remains a crucial preparatory regimen for hematopoietic stem cell transplantation. However, traditional techniques involve complex workflows requiring dual CT simulations-Head-First Supine (HFS) and Feet-First Supine (FFS)-which pose logistical, dosimetric, and patient comfort challenges. This study introduces a simplified TBI approach using a single HFS CT scan combined with Surface Guided Radiation Therapy (SGRT) for setup verification and intra-fraction motion monitoring on the Radixact® TomoTherapy system. <i>Materials and Methods</i>: From August 2024 to April 2025, five adult patients with hematologic malignancies scheduled for TBI were retrospectively analyzed. Each patient underwent a single HFS simulation scan on PET-CT with full-body coverage. Immobilization was achieved using a vacuum cushion and thermoplastic mask. Treatment planning was performed using Accuray Precision® version 3.5.0.2 on a single CT dataset. Two helical plans, one for the upper body and one for the lower body, were generated with a 14 cm overlap at the mid-thigh. Seven feathered Planning Target Volumes (PTVs) were created at the junction to ensure dose homogeneity. Surface Guided Radiation Therapy (SGRT) was used for initial setup and intra-fraction motion monitoring, while ClearRT-based kVCT imaging served as a secondary internal verification. Patient-specific quality assurance (PSQA) was conducted using Delta4 with 3%/3 mm gamma criteria, and junction dose validation was performed using ion chamber measurements. <i>Results</i>: SGRT enabled accurate patient setup for TBI, with mean translational errors ≤2 mm and rotational errors ≤0.6° when compared to kVCT verification. Real-time motion monitoring during treatment enabled automatic beam-holds with an average latency of 0.0038 seconds, ensuring precise delivery. Dosimetric results showed excellent target coverage (≥95% of the PTV receiving ≥95% of the prescribed dose) and homogeneous dose distribution. Smooth dose profiles were observed at plan junctions, and lung doses remained within safe limits (~1.7 Gy). Pre-treatment QA demonstrated high gamma pass rates across all body regions (mean ≥96.6%), confirming treatment accuracy. <i>Discussion</i>: This simple modified workflow utilizing a single HFS CT scan for full-body TBI on Radixact eliminates the need for patient repositioning and FFS imaging, thereby simplifying the planning and delivery process. Integration of SGRT provides non-ionizing, real-time monitoring, enhancing setup precision and intra-fraction control. The feathered PTV junction design effectively mitigated dose inhomogeneities. This method demonstrates not only dosimetric robustness but also improved workflow efficiency and patient comfort.

International Journal of Clinical Oncology and Cancer ResearchVol. 10(3)
Sahyadri Hospital (IN)
Openalex Percentile: Top 77%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.