Different LVRT Performance Analysis of PV Inverters in the Large-Scale Photovoltaic Cluster Transmission by VSC-HVDC

In the sending-end grid of large-scale photovoltaic (PV) cluster transmission by voltage source converter based high voltage direct current (VSC-HVDC), the converters are typically located at considerable distances from one another. When a short circuit fault occurs in the grid, photovoltaic power plants are affected differently due to the different distances of individual PV power plants from the fault point. As a result, PV power plants may enter different low voltage ride through (LVRT) performances and present different performances during the fault. This paper proposes a range of potential LVRT performances that may be arise during grid faults. Simulations of three-phase short circuit faults in the sending-end grid of large-scale photovoltaic cluster transmission by VSC-HVDC at different locations will be performed, to analyze the LVRT performances of PV inverters. Several patterns of LVRT performances will be defined according to the simulation results and provide effective information for the improvement of LVRT control strategies.

Authors

Institutions

Publication Details

Published
2025-04-07
DOI
https://doi.org/10.1109/icpies65420.2025.11070022
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Different LVRT Performance Analysis of PV Inverters in the Large-Scale Photovoltaic Cluster Transmission by VSC-HVDC

Tianyu Li, Xia Chen, Kewei Xu, Xiaobin Zhao et al.
HVDC Systems and Fault Protection
article

Different LVRT Performance Analysis of PV Inverters in the Large-Scale Photovoltaic Cluster Transmission by VSC-HVDC

Tianyu Li, Xia Chen, Kewei Xu, Xiaobin Zhao, Zehao Wang, Biyue Huang
article en

Abstract

In the sending-end grid of large-scale photovoltaic (PV) cluster transmission by voltage source converter based high voltage direct current (VSC-HVDC), the converters are typically located at considerable distances from one another. When a short circuit fault occurs in the grid, photovoltaic power plants are affected differently due to the different distances of individual PV power plants from the fault point. As a result, PV power plants may enter different low voltage ride through (LVRT) performances and present different performances during the fault. This paper proposes a range of potential LVRT performances that may be arise during grid faults. Simulations of three-phase short circuit faults in the sending-end grid of large-scale photovoltaic cluster transmission by VSC-HVDC at different locations will be performed, to analyze the LVRT performances of PV inverters. Several patterns of LVRT performances will be defined according to the simulation results and provide effective information for the improvement of LVRT control strategies.

Electric Power Research Institute (US), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 85%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.