Insulation Health Monitoring of 11 kV XLPE Cable under the Influence of Thermal Stresses

Cross-linked polyethylene (XLPE) cables are widely used in power systems due to their superior electro-mechanical strength. Many aging factors like moisture, voids, bending, gases, and thermal stresses are affecting the insulation of the cable. Thermal stress is one of the major factors that affects cable insulation and deteriorates its life span. This study investigates thermal stresses on the 11 kV, 3 phase, 3x120 sq mm (All Aluminum XLPE SWA), by conducting an insulation resistance (IR) test using C. A 6550 IR tester. The data has been analyzed through megohmmeter software and the remaining lifespan has been evaluated by the Arrhenius model strategy. The results are validated by comparing insulation resistance values under different thermal stress conditions. It was observed that the insulation life span of the test sample was reduced significantly due to thermal stresses. Managing thermal stress is imperative to enhance the longevity and performance of electrical infrastructure, which this research highlights.

Authors

Institutions

Publication Details

Published
2025-04-23
DOI
https://doi.org/10.1109/icetecc65365.2025.11070278
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insulation Health Monitoring of 11 kV XLPE Cable under the Influence of Thermal Stresses

Muhammad Moeen, Abubakar Siddique, Shahid Atiq, Muhammad Raza Ahmad et al.
1 citations
High voltage insulation and dielectric phenomena
0.52
article

Insulation Health Monitoring of 11 kV XLPE Cable under the Influence of Thermal Stresses

Muhammad Moeen, Abubakar Siddique, Shahid Atiq, Muhammad Raza Ahmad, Muhammad Usama Shahid, Abdur Rehman
article en
1 citations

Abstract

Cross-linked polyethylene (XLPE) cables are widely used in power systems due to their superior electro-mechanical strength. Many aging factors like moisture, voids, bending, gases, and thermal stresses are affecting the insulation of the cable. Thermal stress is one of the major factors that affects cable insulation and deteriorates its life span. This study investigates thermal stresses on the 11 kV, 3 phase, 3x120 sq mm (All Aluminum XLPE SWA), by conducting an insulation resistance (IR) test using C. A 6550 IR tester. The data has been analyzed through megohmmeter software and the remaining lifespan has been evaluated by the Arrhenius model strategy. The results are validated by comparing insulation resistance values under different thermal stress conditions. It was observed that the insulation life span of the test sample was reduced significantly due to thermal stresses. Managing thermal stress is imperative to enhance the longevity and performance of electrical infrastructure, which this research highlights.

Khwaja Fareed University of Engineering and Information Technology (PK)
Affordable and clean energy
Openalex Percentile: Top 36%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.