Development of an STM32-Based Noninvasive Hemoglobin Measurement System Using Multiwavelength Photoplethysmography

Continuous hemoglobin (Hb) monitoring can diagnose conditions such as polycythemia, anemia, and various cardiovascular diseases. Current Hb measurement techniques are still invasive, often causing discomfort and pain for the user. Non-invasive Hb measurement is a newer technology that is gaining popularity among researchers. This paper proposes a new non-invasive Hb measurement approach using multiwavelength PPG signals. The transmissive mode PPG sensor and the reflective mode PPG sensor collected real-time PPG signals at four wavelengths: 560 nm, 660 nm, 880 nm, and 940 nm. A novel twenty-six feature vector such as perfusion density (PD), PPG absorbance (ABR), molar extinction coefficient (MEC), magnitude of prominent peak (PPM), frequency of prominent peak (PPF), and absorbance ratio are first time computed in this work from the real-time acquired PPG signal. The performance of the proposed framework is analyzed by utilizing the optimized four different machine learning (ML) regression models such as the AdaBoost model, XGBoost model, BPNN model, and the CatBoost model. Further, this work utilized Shapley Additive Explanations (SHAP) values to visualize the importance of each feature in Hb estimation, enabling a clear understanding of how different features contribute to the prediction process. This SHAP value helps to select the most relevant features for improving the accuracy and interpretability of the Hb estimation model. Results indicate that the BPNN model exhibited superior performance, yielding a mean absolute error (MAE) of 0.421 g/dL, 0.624 g/dL, and 1.57 g/dL for Dataset-1, Dataset-2, and In-house dataset respectively. Additionally, the proposed framework is implemented on an embedded platform featuring an STM32F67ZI microcontroller, showcasing its effectiveness for real-time execution.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3588938
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an STM32-Based Noninvasive Hemoglobin Measurement System Using Multiwavelength Photoplethysmography

Pratibha Maan, Manjeet Kumar, Pankaj
1 citations
IEEE Transactions on Instrumentation and Measurement
Non-Invasive Vital Sign Monitoring
0.67
article

Development of an STM32-Based Noninvasive Hemoglobin Measurement System Using Multiwavelength Photoplethysmography

Pratibha Maan, Manjeet Kumar, Pankaj
article en
1 citations

Abstract

Continuous hemoglobin (Hb) monitoring can diagnose conditions such as polycythemia, anemia, and various cardiovascular diseases. Current Hb measurement techniques are still invasive, often causing discomfort and pain for the user. Non-invasive Hb measurement is a newer technology that is gaining popularity among researchers. This paper proposes a new non-invasive Hb measurement approach using multiwavelength PPG signals. The transmissive mode PPG sensor and the reflective mode PPG sensor collected real-time PPG signals at four wavelengths: 560 nm, 660 nm, 880 nm, and 940 nm. A novel twenty-six feature vector such as perfusion density (PD), PPG absorbance (ABR), molar extinction coefficient (MEC), magnitude of prominent peak (PPM), frequency of prominent peak (PPF), and absorbance ratio are first time computed in this work from the real-time acquired PPG signal. The performance of the proposed framework is analyzed by utilizing the optimized four different machine learning (ML) regression models such as the AdaBoost model, XGBoost model, BPNN model, and the CatBoost model. Further, this work utilized Shapley Additive Explanations (SHAP) values to visualize the importance of each feature in Hb estimation, enabling a clear understanding of how different features contribute to the prediction process. This SHAP value helps to select the most relevant features for improving the accuracy and interpretability of the Hb estimation model. Results indicate that the BPNN model exhibited superior performance, yielding a mean absolute error (MAE) of 0.421 g/dL, 0.624 g/dL, and 1.57 g/dL for Dataset-1, Dataset-2, and In-house dataset respectively. Additionally, the proposed framework is implemented on an embedded platform featuring an STM32F67ZI microcontroller, showcasing its effectiveness for real-time execution.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Govind Ballabh Pant University of Agriculture and Technology (IN), National Institute of Science Communication and Information Resources (IN), Delhi Technological University (IN)
Zero hunger
Openalex Percentile: Top 29%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.