Digitally-Assisted Calibration and Control of a Raster-Scanning System Based on MEMS Mirrors

This work discloses the implementation of a raster-scanning projection system based on MEMS micromirrors, including predictor-based control and an embedded recalibration feature. The system is designed to target an image of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1280\times 720$</tex-math> </inline-formula> pixels. Two separate mirrors are used to steer a single, modulated, laser source across the screen: one, operated at its resonance frequency, performs a sinusoidal horizontal scan, while the second, operated in the quasi-static regime, performs the vertical scan. The maximum frame rate at the target resolution is 60Hz when bidirectional scanning is exploited. The amplitude and frequency errors of the horizontal scan are 18.5 mdeg and 52 ppm, respectively, while the linearity of the vertical scan is 3.4mdeg, i.e., 580ppm of the field-of-view, with a mean frame-to-frame reproducibility of 5.5 mdeg. [2025-0068]

Authors

Institutions

Publication Details

Journal
Journal of Microelectromechanical Systems
Published
2025-01-01
DOI
https://doi.org/10.1109/jmems.2025.3584552
Primary Topic
Astronomical Observations and Instrumentation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digitally-Assisted Calibration and Control of a Raster-Scanning System Based on MEMS Mirrors

Paolo Frigerio, Roberto Carminati, Luca Guido Molinari, Marco Zamprogno et al.
Journal of Microelectromechanical Systems
Astronomical Observations and Instrumentation
article

Digitally-Assisted Calibration and Control of a Raster-Scanning System Based on MEMS Mirrors

Paolo Frigerio, Roberto Carminati, Luca Guido Molinari, Marco Zamprogno, Giacomo Langfelder
article en

Abstract

This work discloses the implementation of a raster-scanning projection system based on MEMS micromirrors, including predictor-based control and an embedded recalibration feature. The system is designed to target an image of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1280\times 720$</tex-math> </inline-formula> pixels. Two separate mirrors are used to steer a single, modulated, laser source across the screen: one, operated at its resonance frequency, performs a sinusoidal horizontal scan, while the second, operated in the quasi-static regime, performs the vertical scan. The maximum frame rate at the target resolution is 60Hz when bidirectional scanning is exploited. The amplitude and frequency errors of the horizontal scan are 18.5 mdeg and 52 ppm, respectively, while the linearity of the vertical scan is 3.4mdeg, i.e., 580ppm of the field-of-view, with a mean frame-to-frame reproducibility of 5.5 mdeg. [2025-0068]

Journal of Microelectromechanical Systems
STMicroelectronics (Italy) (IT), Politecnico di Milano (IT)
Affordable and clean energy
Openalex Percentile: Top 82%
Astronomical Observations and Instrumentation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.