Magnetic noise suppression based on mid-frequency magnetic field response in SERF atomic comagnetometers

The atomic comagnetometers (ACMs) based on the spin-exchange relaxation-free (SERF) regime exhibit extremely high sensitivity in angular velocity measurements, positioning them as leading candidates for next-generation precision inertial sensing. However, magnetic noise remains a significant factor that contributes significantly to long-term bias drift. Here, a comprehensive model in full-frequency band of the angular velocity measurement error induced by magnetic noise in ACMs is established. Based on the proposed model, what we believe to be a new method is proposed to reduce magnetic noise error by suppressing the magnetic field response in the mid-frequency range. After optimizing the temperature of the vapor cell to minimize the magnetic field response in the mid-frequency range, the angular velocity measurement error caused by magnetic noise was reduced by 20.4%, and the bias drift was improved by 34.8%. The theories and methods proposed in this study innovatively highlight the critical role of mid-frequency magnetic field responses in suppressing magnetic noise errors, and provide important guidance for improving bias drift in SERF ACMs.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-07-14
DOI
https://doi.org/10.1364/oe.565442
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic noise suppression based on mid-frequency magnetic field response in SERF atomic comagnetometers

Wei Quan, Ze Cai
Optics Express
Atomic and Subatomic Physics Research
article

Magnetic noise suppression based on mid-frequency magnetic field response in SERF atomic comagnetometers

Wei Quan, Ze Cai
article en

Abstract

The atomic comagnetometers (ACMs) based on the spin-exchange relaxation-free (SERF) regime exhibit extremely high sensitivity in angular velocity measurements, positioning them as leading candidates for next-generation precision inertial sensing. However, magnetic noise remains a significant factor that contributes significantly to long-term bias drift. Here, a comprehensive model in full-frequency band of the angular velocity measurement error induced by magnetic noise in ACMs is established. Based on the proposed model, what we believe to be a new method is proposed to reduce magnetic noise error by suppressing the magnetic field response in the mid-frequency range. After optimizing the temperature of the vapor cell to minimize the magnetic field response in the mid-frequency range, the angular velocity measurement error caused by magnetic noise was reduced by 20.4%, and the bias drift was improved by 34.8%. The theories and methods proposed in this study innovatively highlight the critical role of mid-frequency magnetic field responses in suppressing magnetic noise errors, and provide important guidance for improving bias drift in SERF ACMs.

Optics ExpressVol. 33(16)
Hefei University (CN)
Affordable and clean energy
Openalex Percentile: Top 87%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.