Temperature dependence of response of a pH glass electrode for environmental measurement

During the continuous monitoring of pH in environmental water, the temperature of the environmental water changes at each moment. Coral reefs are likely to be strongly affected by ocean acidification, so accurate and continuous pH monitoring is important. On the other hands, the water temperature in coral reef areas varies greatly not only due to solar radiation but also due to the mixing of open ocean water and land water. This temperature variation affects the accurate pH measurement. Preparing calibration values for the pH electrodes at all water temperatures is impossible, but the monitoring accuracy could be improved by predicting the constituent values at the on-site water temperature from the electrode calibration results at one or two temperatures. Therefore, we calibrate the pH at one or two temperatures and use the result for estimating the calibration value at another temperature. For this purpose, we estimated the pH change of the internal liquid of the electrode (assumed as a phosphate buffer) under saturated and unsaturated conditions of the coexisting KCl in the buffer.

Authors

Institutions

Publication Details

Journal
Galaxea Journal of Coral Reef Studies
Published
2025-01-01
DOI
https://doi.org/10.3755/galaxea.g27o-4
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature dependence of response of a pH glass electrode for environmental measurement

Takuroh Noguchi, Mayumi Hatta, Kei Okamura
4 links
Galaxea Journal of Coral Reef Studies
Analytical Chemistry and Sensors
article

Temperature dependence of response of a pH glass electrode for environmental measurement

Takuroh Noguchi, Mayumi Hatta, Kei Okamura
article en

Abstract

During the continuous monitoring of pH in environmental water, the temperature of the environmental water changes at each moment. Coral reefs are likely to be strongly affected by ocean acidification, so accurate and continuous pH monitoring is important. On the other hands, the water temperature in coral reef areas varies greatly not only due to solar radiation but also due to the mixing of open ocean water and land water. This temperature variation affects the accurate pH measurement. Preparing calibration values for the pH electrodes at all water temperatures is impossible, but the monitoring accuracy could be improved by predicting the constituent values at the on-site water temperature from the electrode calibration results at one or two temperatures. Therefore, we calibrate the pH at one or two temperatures and use the result for estimating the calibration value at another temperature. For this purpose, we estimated the pH change of the internal liquid of the electrode (assumed as a phosphate buffer) under saturated and unsaturated conditions of the coexisting KCl in the buffer.

Galaxea Journal of Coral Reef StudiesVol. 27(1)
Kōchi University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 78%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Temperature dependence of response of a pH glass electrode for environmental measurement — Takuroh Noguchi, Mayumi Hatta, et al. · Galaxea Journal of Coral Reef Studies (2025) | TGRS Research Map | TGRS