Mixture Detection Using a Deep-UV Raman-LIBS Autofocus-Based Compact Chemical Spectroscopic Sensor

We present a compact, multifunctional chemical sensor that seamlessly integrates deep-UV Raman and laser-induced breakdown spectroscopy (LIBS) modalities into a single lightweight hand-held unit. By employing a single 266 nm laser source (1.5 ns pulse width, 10 mW average power) and an integrated autofocus mechanism, this design overcomes the complexities associated with systems that rely on dual or multiple laser wavelengths (e.g., 532 or 1064 nm). The 3D-printed sensor body weighs only 38 g and occupies a compact volume of 70 × 60 × 40 mm<sup>3</sup> (that can fit within a palm of a hand) enabling comfortable hand-held operation in both laboratory and field environments. When combined with a 215 g deep-UV compact laser unit and a 90 g compact but high-resolution spectrometer (which is possible only with deep-UV operation), the overall system weight remains under 500 g, reinforcing its suitability for highly mobile applications. The functionality of the sensor is demonstrated for mixture detection in (a) a complex mineral-planetary simulant mixture, (b) isotope mixture, and (c) an organic-inorganic mixture. The deep-UV 266 nm operation allowed mixture detection to as low as 0.1% with such a compact sensor, which is only possible with bulky intensified CCDs previously reported with visible/IR wavelengths. The deep-UV excitation enhances Raman signal strength and reduces fluorescence interference, while the integrated autofocus capability facilitates seamless switching between LIBS and Raman operation modes. Compared to existing integrated approaches, this single-laser design significantly reduces optical complexity and overall system footprint, offering a robust solution for in situ chemical analyses ranging from environmental monitoring to planetary exploration.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-07-14
DOI
https://doi.org/10.1021/acsomega.5c03801
Citations
3
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
4.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mixture Detection Using a Deep-UV Raman-LIBS Autofocus-Based Compact Chemical Spectroscopic Sensor

Narasimha S. Prasad, Atchutananda Surampudi, D. M. Bower, Mool C. Gupta et al.
3 citations
ACS Omega
Spectroscopy Techniques in Biomedical and Chemical Research
4.90
article

Mixture Detection Using a Deep-UV Raman-LIBS Autofocus-Based Compact Chemical Spectroscopic Sensor

Narasimha S. Prasad, Atchutananda Surampudi, D. M. Bower, Mool C. Gupta, T. Hewagama, Anil Aryal
article en
3 citations

Abstract

We present a compact, multifunctional chemical sensor that seamlessly integrates deep-UV Raman and laser-induced breakdown spectroscopy (LIBS) modalities into a single lightweight hand-held unit. By employing a single 266 nm laser source (1.5 ns pulse width, 10 mW average power) and an integrated autofocus mechanism, this design overcomes the complexities associated with systems that rely on dual or multiple laser wavelengths (e.g., 532 or 1064 nm). The 3D-printed sensor body weighs only 38 g and occupies a compact volume of 70 × 60 × 40 mm<sup>3</sup> (that can fit within a palm of a hand) enabling comfortable hand-held operation in both laboratory and field environments. When combined with a 215 g deep-UV compact laser unit and a 90 g compact but high-resolution spectrometer (which is possible only with deep-UV operation), the overall system weight remains under 500 g, reinforcing its suitability for highly mobile applications. The functionality of the sensor is demonstrated for mixture detection in (a) a complex mineral-planetary simulant mixture, (b) isotope mixture, and (c) an organic-inorganic mixture. The deep-UV 266 nm operation allowed mixture detection to as low as 0.1% with such a compact sensor, which is only possible with bulky intensified CCDs previously reported with visible/IR wavelengths. The deep-UV excitation enhances Raman signal strength and reduces fluorescence interference, while the integrated autofocus capability facilitates seamless switching between LIBS and Raman operation modes. Compared to existing integrated approaches, this single-laser design significantly reduces optical complexity and overall system footprint, offering a robust solution for in situ chemical analyses ranging from environmental monitoring to planetary exploration.

ACS OmegaVol. 10(30)
Goddard Space Flight Center (US), Langley Research Center (US), Urology of Virginia (US), Laser & Plasma Technologies (United States) (US), University of Virginia (US), University of Maryland, College Park (US)
NASA Headquarters
Openalex Percentile: Top 5%
Spectroscopy Techniques in Biomedical and Chemical Research
4.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.