Studies on the Partitioning of Furfural Between Liquid and Paper Insulation

Ageing status of transformer paper insulation is commonly assessed through measured 2-furfural in oil. Laboratory studies have shown an exponential increase in 2-furfural in oil with the reduction in the Degree of Polymerisation (DP) of paper insulation. While there have been various models proposed to estimate the DP of paper insulation through 2-furfural in liquid, their applicability has been a challenging task due to the complex partitioning process between oil and paper for in-service power transformers. This paper investigates the applicability of Van't Hoff plots for temperature correction of measured 2-furfural in oil for oil-paper insulation systems through literature data and laboratory studies. Laboratory study was conducted with mineral oil and two types of paper: non-thermally upgraded Kraft paper and thermally upgraded Kraft paper. Furthermore, effects of temperature and water content on the partitioning process were evaluated. Results from both literature and experiments indicated that Van't Hoff plots could be used for identifying temperature correction factors for 2- furfural measurements.

Authors

Institutions

Publication Details

Published
2025-05-18
DOI
https://doi.org/10.1109/icdl63868.2025.11068241
Primary Topic
Advanced Cellulose Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Studies on the Partitioning of Furfural Between Liquid and Paper Insulation

Zhongdong Wang, Shanika Matharage, Saurabh Dutta, Gordon Wilson
Advanced Cellulose Research Studies
article

Studies on the Partitioning of Furfural Between Liquid and Paper Insulation

Zhongdong Wang, Shanika Matharage, Saurabh Dutta, Gordon Wilson
article en

Abstract

Ageing status of transformer paper insulation is commonly assessed through measured 2-furfural in oil. Laboratory studies have shown an exponential increase in 2-furfural in oil with the reduction in the Degree of Polymerisation (DP) of paper insulation. While there have been various models proposed to estimate the DP of paper insulation through 2-furfural in liquid, their applicability has been a challenging task due to the complex partitioning process between oil and paper for in-service power transformers. This paper investigates the applicability of Van't Hoff plots for temperature correction of measured 2-furfural in oil for oil-paper insulation systems through literature data and laboratory studies. Laboratory study was conducted with mineral oil and two types of paper: non-thermally upgraded Kraft paper and thermally upgraded Kraft paper. Furthermore, effects of temperature and water content on the partitioning process were evaluated. Results from both literature and experiments indicated that Van't Hoff plots could be used for identifying temperature correction factors for 2- furfural measurements.

University of Manchester (GB), National Grid (United Kingdom) (GB)
Openalex Percentile: Top 90%
Advanced Cellulose Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.