Partial Discharge Analysis of Natural Ester Oil Based Nanofluid Impregnated Pressboard Insulation

The transformer insulation system relies on solid and liquid insulation for safe and efficient operation, directly impacting lifespan. Various nanoparticles (NPs) have been introduced in liquid insulation to enhance dielectric properties, but issues like agglomeration limit their effectiveness. To overcome this limitation of agglomeration, the NPs are impregnated on the surface of the pressboard insulation, offering stable thermal and electrical performance. It is established in the previous literature that the addition of these NPs in solid insulation will suppress the partial discharge (PD) generated but it is not been extensively studied. So, in this work, an extensive study is conducted to analyze the effect of the NPs on the suppression of PD in the pressboard insulation. In this paper, the PD analysis is carried out for natural ester oil (NEO) based nanofluid-impregnated pressboard (NFIPB) insulation. These samples are compared with mineral oil (MO) NFIPB insulation for comparison pur-poses. This study uses two types of NP: insulating -TiO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>, and semiconducting -ZnO NPs. The pressboard samples are modified with NPs through weight-to-volume concentrations of 0.05 wt% and 0.1 wt% for TiO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> and ZnO. Scanning electron microscopy (SEM) analyses the NP dispersion on NFIPBs. PD tests follow IEC 60270, measuring PD inception voltage (PDIV) per IEC TR 61294 and phase-resolved partial discharge (PRPD) patterns for all the NFIPB samples. The study explores the impact of NPs on PDIV and PRPD patterns, emphasizing their role in improving PD performance.

Authors

Institutions

Publication Details

Published
2025-05-18
DOI
https://doi.org/10.1109/icdl63868.2025.11068274
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial Discharge Analysis of Natural Ester Oil Based Nanofluid Impregnated Pressboard Insulation

Sisir Kumar Nayak, Thirumurugan Chandrasekaran, Sritam Swapnadarshi Sahu, Deepak Kanumuri
Power Transformer Diagnostics and Insulation
article

Partial Discharge Analysis of Natural Ester Oil Based Nanofluid Impregnated Pressboard Insulation

Sisir Kumar Nayak, Thirumurugan Chandrasekaran, Sritam Swapnadarshi Sahu, Deepak Kanumuri
article en

Abstract

The transformer insulation system relies on solid and liquid insulation for safe and efficient operation, directly impacting lifespan. Various nanoparticles (NPs) have been introduced in liquid insulation to enhance dielectric properties, but issues like agglomeration limit their effectiveness. To overcome this limitation of agglomeration, the NPs are impregnated on the surface of the pressboard insulation, offering stable thermal and electrical performance. It is established in the previous literature that the addition of these NPs in solid insulation will suppress the partial discharge (PD) generated but it is not been extensively studied. So, in this work, an extensive study is conducted to analyze the effect of the NPs on the suppression of PD in the pressboard insulation. In this paper, the PD analysis is carried out for natural ester oil (NEO) based nanofluid-impregnated pressboard (NFIPB) insulation. These samples are compared with mineral oil (MO) NFIPB insulation for comparison pur-poses. This study uses two types of NP: insulating -TiO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>, and semiconducting -ZnO NPs. The pressboard samples are modified with NPs through weight-to-volume concentrations of 0.05 wt% and 0.1 wt% for TiO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> and ZnO. Scanning electron microscopy (SEM) analyses the NP dispersion on NFIPBs. PD tests follow IEC 60270, measuring PD inception voltage (PDIV) per IEC TR 61294 and phase-resolved partial discharge (PRPD) patterns for all the NFIPB samples. The study explores the impact of NPs on PDIV and PRPD patterns, emphasizing their role in improving PD performance.

Indian Institute of Technology Guwahati (IN), University of Warwick (GB)
Science and Engineering Research Board
Openalex Percentile: Top 85%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.