Pre-treated pencil graphite modified electrode sensor for melatonin

Since hormones are essential for controlling a wide range of physiological processes in living organisms, sensitive and precise hormone detection methods are needed. In this work, a pencil graphite electrode was pre-treated in 0.1 M KOH solution over many potential cycles. A potential pretreated pencil graphite modified electrode (PPGME) was developed for detecting bioactive molecules and the hormone melatonin (MEL), using phosphate buffer solution as the supporting electrolyte. Various electrochemical parameters, including pH effects, sweep rates, and studies of different concentrations, were investigated for the determination of melatonin. The PPGME was employed for the simultaneous analysis of melatonin and paracetamol. Interference studies for both analytes showed excellent selectivity and a significant peak current response using the PPGME. The detection limit for MEL was determined to be 0.442 µM and this modified PPGME was also applied for the detection and recovery of MEL in a pharmaceutical sample.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Science and Engineering
Published
2025-04-14
DOI
https://doi.org/10.5599/jese.2594
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pre-treated pencil graphite modified electrode sensor for melatonin

Manjappa Siddalinganahalli, L.S. Manjunatha, B.E. Kumara Swamy, Bindu Pavan Venkatachala
1 citations
Journal of Electrochemical Science and Engineering
Electrochemical sensors and biosensors
0.73
article

Pre-treated pencil graphite modified electrode sensor for melatonin

Manjappa Siddalinganahalli, L.S. Manjunatha, B.E. Kumara Swamy, Bindu Pavan Venkatachala
article en
1 citations

Abstract

Since hormones are essential for controlling a wide range of physiological processes in living organisms, sensitive and precise hormone detection methods are needed. In this work, a pencil graphite electrode was pre-treated in 0.1 M KOH solution over many potential cycles. A potential pretreated pencil graphite modified electrode (PPGME) was developed for detecting bioactive molecules and the hormone melatonin (MEL), using phosphate buffer solution as the supporting electrolyte. Various electrochemical parameters, including pH effects, sweep rates, and studies of different concentrations, were investigated for the determination of melatonin. The PPGME was employed for the simultaneous analysis of melatonin and paracetamol. Interference studies for both analytes showed excellent selectivity and a significant peak current response using the PPGME. The detection limit for MEL was determined to be 0.442 µM and this modified PPGME was also applied for the detection and recovery of MEL in a pharmaceutical sample.

Journal of Electrochemical Science and EngineeringVol. 15(5)
Kuvempu University (IN), Visvesvaraya Technological University (IN)
Openalex Percentile: Top 26%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pre-treated pencil graphite modified electrode sensor for melatonin — Manjappa Siddalinganahalli, L.S. Manjunatha, et al. · Journal of Electrochemical Science and Engineering (2025) | TGRS Research Map | TGRS