Ultrahigh-Sensitivity 3D-Printed Hollow Fabry-Pérot Fiber Ultrasound Sensor for Photoacoustic Imaging

Photoacoustic imaging is an advanced imaging technique that requires highly sensitive ultrasonic detectors to capture weak high-frequency signals. Optical ultrasound sensors, particularly Fabry–Pérot (FP) interferometers, offer a promising alternative with improved sensitivity, compact size, and electromagnetic immunity. However, traditional deposition-based FP fiber sensors, which rely on solid spacers, are mechanically constrained, limiting further sensitivity improvements. Existing printed structures are unable to achieve the high-frequency response required for photoacoustic imaging. In this work, we present an ultrahigh-sensitivity hollow FP fiber sensor fabricated by two-photon polymerization 3D printing and vapor deposition. The unique hollow design reduces the backing resistance limitations of the response film typically seen in solid FP sensors, resulting in improved displacement sensitivity with a high frequency response. The sensor achieves a total sensitivity of 797 mV/kPa, which is 22× higher than that of the conventional solid FP sensor, with a low noise-equivalent pressure of 2.8 Pa. It operates at a central response frequency of 1.5 MHz with a bandwidth of 1.2 MHz and features a wide response angle of 180°, which minimizes blind spots. Additionally, we developed a photoacoustic imaging system based on this sensor, achieving a resolution of 117 μm. This hollow FP fiber sensor offers a robust solution for high-precision ultrasound detection and imaging, enabling advanced photoacoustic imaging applications in the future.

Authors

Institutions

Publication Details

Journal
ACS Photonics
Published
2025-07-14
DOI
https://doi.org/10.1021/acsphotonics.5c00944
Citations
4
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
2.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrahigh-Sensitivity 3D-Printed Hollow Fabry-Pérot Fiber Ultrasound Sensor for Photoacoustic Imaging

Zhi Zhang, Wei Xiong, Zongjin Li, Xuhao Fan et al.
4 citations
ACS Photonics
Photoacoustic and Ultrasonic Imaging
2.70
article

Ultrahigh-Sensitivity 3D-Printed Hollow Fabry-Pérot Fiber Ultrasound Sensor for Photoacoustic Imaging

Zhi Zhang, Wei Xiong, Zongjin Li, Xuhao Fan, Zexu Zhang, Yueqi Liu, Haiyang Qiu, Hui Gao, Hao Li, Anqi Wang, Qizhen Sun, Geng Chen, Xinger Wang
article en
4 citations

Abstract

Photoacoustic imaging is an advanced imaging technique that requires highly sensitive ultrasonic detectors to capture weak high-frequency signals. Optical ultrasound sensors, particularly Fabry–Pérot (FP) interferometers, offer a promising alternative with improved sensitivity, compact size, and electromagnetic immunity. However, traditional deposition-based FP fiber sensors, which rely on solid spacers, are mechanically constrained, limiting further sensitivity improvements. Existing printed structures are unable to achieve the high-frequency response required for photoacoustic imaging. In this work, we present an ultrahigh-sensitivity hollow FP fiber sensor fabricated by two-photon polymerization 3D printing and vapor deposition. The unique hollow design reduces the backing resistance limitations of the response film typically seen in solid FP sensors, resulting in improved displacement sensitivity with a high frequency response. The sensor achieves a total sensitivity of 797 mV/kPa, which is 22× higher than that of the conventional solid FP sensor, with a low noise-equivalent pressure of 2.8 Pa. It operates at a central response frequency of 1.5 MHz with a bandwidth of 1.2 MHz and features a wide response angle of 180°, which minimizes blind spots. Additionally, we developed a photoacoustic imaging system based on this sensor, achieving a resolution of 117 μm. This hollow FP fiber sensor offers a robust solution for high-precision ultrasound detection and imaging, enabling advanced photoacoustic imaging applications in the future.

ACS PhotonicsVol. 12(8)
Next Generation Technology (United States) (US), Wuhan National Laboratory for Optoelectronics (CN), Huazhong University of Science and Technology (CN), Wuxi Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
Photoacoustic and Ultrasonic Imaging
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.