Impact of Hydrogen-Enriched Natural Gas on the Accuracy of Odorant Measurements

Blending hydrogen with natural gas is emerging as a pivotal strategy in the transition to low-carbon energy systems. However, the exploitation of the natural gas infrastructure to distribute natural gas and hydrogen blends (and 100% hydrogen in the long-term) introduces several technical, economic, and safety issues. These latter are paramount, especially in urban distribution networks that supply residential buildings and dwellings, since the quality and safety of the living environment can also be significantly affected. In this scenario, the reliability of odorant concentration measurements according to the best practices currently in use for natural gas becomes crucial. This study is aimed at assessing the accuracy of odorant measurements at different concentration levels (i.e., low, medium, and high) in 100% methane, methane-hydrogen blend and 100% hydrogen. The obtained results show the tendency to overestimate the odorant concentration up to 2.3% in methane-hydrogen blends at medium and high concentrations of THT as well as the underestimation of -3.4% in 100% hydrogen at low concentration of TBM. These results are consistent with those of natural gas from the city distribution network with hydrogen content of 5% and 20%.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-07-14
DOI
https://doi.org/10.3390/s25144394
Citations
3
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Hydrogen-Enriched Natural Gas on the Accuracy of Odorant Measurements

Giulia Monteleone, Giorgio Ficco, G. Cortellessa, Viviana Cigolotti et al.
3 citations
Sensors
Advanced Chemical Sensor Technologies
2.02
article

Impact of Hydrogen-Enriched Natural Gas on the Accuracy of Odorant Measurements

Giulia Monteleone, Giorgio Ficco, G. Cortellessa, Viviana Cigolotti, Marco Dell’Isola
article en
3 citations

Abstract

Blending hydrogen with natural gas is emerging as a pivotal strategy in the transition to low-carbon energy systems. However, the exploitation of the natural gas infrastructure to distribute natural gas and hydrogen blends (and 100% hydrogen in the long-term) introduces several technical, economic, and safety issues. These latter are paramount, especially in urban distribution networks that supply residential buildings and dwellings, since the quality and safety of the living environment can also be significantly affected. In this scenario, the reliability of odorant concentration measurements according to the best practices currently in use for natural gas becomes crucial. This study is aimed at assessing the accuracy of odorant measurements at different concentration levels (i.e., low, medium, and high) in 100% methane, methane-hydrogen blend and 100% hydrogen. The obtained results show the tendency to overestimate the odorant concentration up to 2.3% in methane-hydrogen blends at medium and high concentrations of THT as well as the underestimation of -3.4% in 100% hydrogen at low concentration of TBM. These results are consistent with those of natural gas from the city distribution network with hydrogen content of 5% and 20%.

SensorsVol. 25(14)
National Agency for New Technologies, Energy and Sustainable Economic Development (IT), Università degli studi di Cassino e del Lazio Meridionale (IT)
Ministry of Environment
Sustainable cities and communities
Openalex Percentile: Top 13%
Advanced Chemical Sensor Technologies
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.