Differentiation of lactose sample batches from surface impurities by OrbiSIMS

Impurities present on the surface of pharmaceutical formulations for drug delivery significantly impact their stability and efficacy. Hence, the characterization of impurities on the surface is essential to ensure efficacy, quality, and safety. Secondary ion mass spectrometry (SIMS) is gaining increasing popularity for surface analysis in the pharmaceutical industry, due to its high sensitivity and spatial resolution. Time-of-Flight (ToF) SIMS instruments have been successfully used. However, their application has been limited since the mass resolving power and mass accuracy are too low to separate complex peaks and give identification with confidence. The OrbiSIMS instrument overcomes this issue owing to its Orbitrap analyzer with a mass resolving power of >240 000 at <i>m</i>/<i>z</i> 200 and a mass accuracy of <2 ppm. We use the OrbiSIMS in combination with multivariate analysis to differentiate notionally identical batches of lactose from different suppliers using the detection of small differences in surface impurities.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2025-01-01
DOI
https://doi.org/10.1039/d5an00364d
Citations
1
Primary Topic
Ion-surface interactions and analysis
Type
article
Field-Weighted Citation Impact
1.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differentiation of lactose sample batches from surface impurities by OrbiSIMS

Eleonora Paladino, Paulina D. Rakowska, Ian S. Gilmore, Tony Bristow et al.
1 citations
The Analyst
Ion-surface interactions and analysis
1.33
article

Differentiation of lactose sample batches from surface impurities by OrbiSIMS

Eleonora Paladino, Paulina D. Rakowska, Ian S. Gilmore, Tony Bristow, Bin Yan, Mark Nicholas, Junting Zhang
article en
1 citations

Abstract

Impurities present on the surface of pharmaceutical formulations for drug delivery significantly impact their stability and efficacy. Hence, the characterization of impurities on the surface is essential to ensure efficacy, quality, and safety. Secondary ion mass spectrometry (SIMS) is gaining increasing popularity for surface analysis in the pharmaceutical industry, due to its high sensitivity and spatial resolution. Time-of-Flight (ToF) SIMS instruments have been successfully used. However, their application has been limited since the mass resolving power and mass accuracy are too low to separate complex peaks and give identification with confidence. The OrbiSIMS instrument overcomes this issue owing to its Orbitrap analyzer with a mass resolving power of >240 000 at <i>m</i>/<i>z</i> 200 and a mass accuracy of <2 ppm. We use the OrbiSIMS in combination with multivariate analysis to differentiate notionally identical batches of lactose from different suppliers using the detection of small differences in surface impurities.

The AnalystVol. 150(16)
AstraZeneca (United Kingdom) (GB), National Physical Laboratory (GB), AstraZeneca (Netherlands) (NL), University of Southampton (GB)
UK Research and Innovation
Openalex Percentile: Top 21%
Ion-surface interactions and analysis
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Differentiation of lactose sample batches from surface impurities by OrbiSIMS — Eleonora Paladino, Paulina D. Rakowska, et al. · The Analyst (2025) | TGRS Research Map | TGRS