High-Performance Guided Mode Resonance Optofluidic Sensor

This paper reports on the high performance of a thick-waveguide guided mode resonance (GMR) sensor. Theoretical calculations revealed that when light incidents on the grating and excites the negative first-order diffraction order, by increasing the waveguide thickness, both a high sensitivity and high figure of merit (FOM) can be obtained. Experimentally, we achieved a sensitivity of 1255.78 nm/RIU, a resonance linewidth of 0.59 nm at the resonance wavelength of 535 nm, an FOM as high as 2128 RIU<sup>-1</sup>, and a detection limit as low as 1.74 × 10<sup>-7</sup> RIU. To our knowledge, this performance represents the highest comprehensive level for current GMR sensors. Additionally, the use of a microfluidic hemisphere and polymer materials effectively reduces the liquid consumption under oblique incidence and the fabrication cost in practical application. Overall, the proposed GMR sensor exhibits great potential in label-free biosensing.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-07-14
DOI
https://doi.org/10.3390/s25144386
Citations
2
Primary Topic
Optical Coatings and Gratings
Type
article
Field-Weighted Citation Impact
1.32

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Performance Guided Mode Resonance Optofluidic Sensor

Liying Liu, Lei Xu, Guo Liang
2 citations
Sensors
Optical Coatings and Gratings
1.32
article

High-Performance Guided Mode Resonance Optofluidic Sensor

Liying Liu, Lei Xu, Guo Liang
article en
2 citations

Abstract

This paper reports on the high performance of a thick-waveguide guided mode resonance (GMR) sensor. Theoretical calculations revealed that when light incidents on the grating and excites the negative first-order diffraction order, by increasing the waveguide thickness, both a high sensitivity and high figure of merit (FOM) can be obtained. Experimentally, we achieved a sensitivity of 1255.78 nm/RIU, a resonance linewidth of 0.59 nm at the resonance wavelength of 535 nm, an FOM as high as 2128 RIU<sup>-1</sup>, and a detection limit as low as 1.74 × 10<sup>-7</sup> RIU. To our knowledge, this performance represents the highest comprehensive level for current GMR sensors. Additionally, the use of a microfluidic hemisphere and polymer materials effectively reduces the liquid consumption under oblique incidence and the fabrication cost in practical application. Overall, the proposed GMR sensor exhibits great potential in label-free biosensing.

SensorsVol. 25(14)
Fudan University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 19%
Optical Coatings and Gratings
1.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Performance Guided Mode Resonance Optofluidic Sensor — Liying Liu, Lei Xu, et al. · Sensors (2025) | TGRS Research Map | TGRS