Elucidating the high compliance mechanism by which the urinary bladder fills under low pressures

The high compliance of the urinary bladder during filling is essential for its proper function, enabling it to accommodate significant volumetric increases with minimal rise in transmural pressure. This study aimed to elucidate the physical mechanisms underlying this phenomenon by analyzing the ex vivo filling process in rat from a fully voided state to complete distension, without preconditioning, using three complementary imaging modalities. High-resolution micro-CT at 10.8 [Formula: see text]m resolution was used to generate detailed 3D reconstructions of the bladder lumen, revealing an average 62-fold increase in bladder volume during filling. Pressure-volume studies of whole bladder delineated three mechanical filling regimes: an initial high-compliance phase, a transitional phase, and a final high-pressure phase. While prior studies conjectured small mucosal rugae (∼450 [Formula: see text]m) are responsible for the high compliance phase, multiphoton microscopy (MPM) of the dome of the voided bladder revealed large folds in voided bladders an order of magnitude larger than these rugae. Bladder imaging during the inflation process demonstrated flattening of these large scale folds in the initial high compliance phase. The 3D reconstructions of the bladder lumen in the filled and voided state revealed a high voiding efficiency of 97.13% ± 2.42%. The MPM imaging results suggest the large scale folds in the dome enable this high voiding fraction by driving urine toward the bladder outlet. These insights are vital for developing realistic computational models of bladder micturition and understanding changes to bladder function due to pathological conditions such as bladder outlet obstruction and age-related dysfunction.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-07-14
DOI
https://doi.org/10.1038/s41598-025-07479-4
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elucidating the high compliance mechanism by which the urinary bladder fills under low pressures

Lori A. Birder, Paul N. Watton, Christopher Hardin, Yasutaka Tobe et al.
2 links
Scientific Reports
Urinary Bladder and Prostate Research
article

Elucidating the high compliance mechanism by which the urinary bladder fills under low pressures

Lori A. Birder, Paul N. Watton, Christopher Hardin, Yasutaka Tobe, Kanako Matsuoka, Anne M. Robertson, Simon C. Watkins, Fatemeh Azari
article en

Abstract

The high compliance of the urinary bladder during filling is essential for its proper function, enabling it to accommodate significant volumetric increases with minimal rise in transmural pressure. This study aimed to elucidate the physical mechanisms underlying this phenomenon by analyzing the ex vivo filling process in rat from a fully voided state to complete distension, without preconditioning, using three complementary imaging modalities. High-resolution micro-CT at 10.8 [Formula: see text]m resolution was used to generate detailed 3D reconstructions of the bladder lumen, revealing an average 62-fold increase in bladder volume during filling. Pressure-volume studies of whole bladder delineated three mechanical filling regimes: an initial high-compliance phase, a transitional phase, and a final high-pressure phase. While prior studies conjectured small mucosal rugae (∼450 [Formula: see text]m) are responsible for the high compliance phase, multiphoton microscopy (MPM) of the dome of the voided bladder revealed large folds in voided bladders an order of magnitude larger than these rugae. Bladder imaging during the inflation process demonstrated flattening of these large scale folds in the initial high compliance phase. The 3D reconstructions of the bladder lumen in the filled and voided state revealed a high voiding efficiency of 97.13% ± 2.42%. The MPM imaging results suggest the large scale folds in the dome enable this high voiding fraction by driving urine toward the bladder outlet. These insights are vital for developing realistic computational models of bladder micturition and understanding changes to bladder function due to pathological conditions such as bladder outlet obstruction and age-related dysfunction.

Scientific ReportsVol. 15(1)
University of Pittsburgh (US), Insigneo (GB), University of Missouri (US)
National Institutes of Health
Zero hunger
Openalex Percentile: Top 76%
Urinary Bladder and Prostate Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.