Assessment of Cancer Risk from Fluorscopic Bile Duct Examinations at Sanjiwani Hospital, Gianyar

Aim: Study on the Assessment of Cancer Risk from Fluoroscopic Bile Duct Examinations at Sanjiwani Hospital, Gianyar the aim is to determine the magnitude of the effective dose received by bile duct patients during fluoroscopic, to determine whether there is a difference between male and female patients in terms of the effective dose, and to determine the risk of cancer in bile duct examinations using fluoroscopic. Study Design: This study uses a quantitative analysis design using secondary data. This study was conducted at the Radiology Unit of Sanjiwani Gianyar Hospital from December 2024 to Febuary 2025. Methodology: This study involved 30 biliary tract patients. Data were analyzed using IBM SPSS and Excel software and for statistical tests using normality test, homogeneity test, one-way t-test, and one WAY ANOVA test to determine the risk of cancer in biliary tract examination with fluoroscopic. Results: After carrying out t-test for the absorbed dose, effective dose and cancer risk which were compared with the BAPETEN and ICRP values, the following result were obtained namely where the absorbed dose value was found to be below the safe threshold set by BAPETEN, which is 50 mGy. And where the effective dose value was found to be below the safe threshold set by BAPETEN, which is 10 mSv. And for the cancer risk value, it was found to be below the safe threshold set by ICRP, which is 0.08%. Conclusion: It is known that the values for the absorbed dose, effective dose, and risk of cancer received by patients at Sanjiwani Gianyar Regional Hospital are still below the values set by BAPETEN and ICRP so that they do not endanger patients undergoing bile duct cancer treatment at the Sanjiwani Gianyar Radiology Installation.

Authors

Institutions

Publication Details

Journal
Asian Journal of Medicine and Health
Published
2025-07-14
DOI
https://doi.org/10.9734/ajmah/2025/v23i71272
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Cancer Risk from Fluorscopic Bile Duct Examinations at Sanjiwani Hospital, Gianyar

Ida Bagus Alit Paramarta, I Nengah Sandi, Anak Agung Ngurah Gunawan, I. Gusti Ayu Ratnawati et al.
Asian Journal of Medicine and Health
Gallbladder and Bile Duct Disorders
article

Assessment of Cancer Risk from Fluorscopic Bile Duct Examinations at Sanjiwani Hospital, Gianyar

Ida Bagus Alit Paramarta, I Nengah Sandi, Anak Agung Ngurah Gunawan, I. Gusti Ayu Ratnawati, Ni Nyoman Ratini, Gusti Widhi Ratih Saraswati
article en

Abstract

Aim: Study on the Assessment of Cancer Risk from Fluoroscopic Bile Duct Examinations at Sanjiwani Hospital, Gianyar the aim is to determine the magnitude of the effective dose received by bile duct patients during fluoroscopic, to determine whether there is a difference between male and female patients in terms of the effective dose, and to determine the risk of cancer in bile duct examinations using fluoroscopic. Study Design: This study uses a quantitative analysis design using secondary data. This study was conducted at the Radiology Unit of Sanjiwani Gianyar Hospital from December 2024 to Febuary 2025. Methodology: This study involved 30 biliary tract patients. Data were analyzed using IBM SPSS and Excel software and for statistical tests using normality test, homogeneity test, one-way t-test, and one WAY ANOVA test to determine the risk of cancer in biliary tract examination with fluoroscopic. Results: After carrying out t-test for the absorbed dose, effective dose and cancer risk which were compared with the BAPETEN and ICRP values, the following result were obtained namely where the absorbed dose value was found to be below the safe threshold set by BAPETEN, which is 50 mGy. And where the effective dose value was found to be below the safe threshold set by BAPETEN, which is 10 mSv. And for the cancer risk value, it was found to be below the safe threshold set by ICRP, which is 0.08%. Conclusion: It is known that the values for the absorbed dose, effective dose, and risk of cancer received by patients at Sanjiwani Gianyar Regional Hospital are still below the values set by BAPETEN and ICRP so that they do not endanger patients undergoing bile duct cancer treatment at the Sanjiwani Gianyar Radiology Installation.

Asian Journal of Medicine and HealthVol. 23(7)
Udayana University (ID)
Openalex Percentile: Top 73%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of Cancer Risk from Fluorscopic Bile Duct Examinations at Sanjiwani Hospital, Gianyar — Ida Bagus Alit Paramarta, I Nengah Sandi, et al. · Asian Journal of Medicine and Health (2025) | TGRS Research Map | TGRS