A Method Based on CNN–BiLSTM–Attention for Wind Farm Line Fault Distance Prediction

In view of the complex operating environments of wind farms and the characteristics of multi-branch mixed collector lines, in order to improve the accuracy of single-phase grounding fault location, the convolutional neural network (CNN), bidirectional long short-term memory network (BiLSTM), and attention mechanism (attention) were combined to construct a single-phase grounding fault location strategy for the CNN–BiLSTM–attention hybrid model. Using a zero-sequence current as the fault information identification method, through the deep fusion of the CNN–BiLSTM–attention hybrid model, the single-phase grounding faults in the collector lines of the wind farm can be located. The simulation modeling was carried out using the MATLAB R2022b software, and the effectiveness of the hybrid model in the single-phase grounding fault location of multi-branch mixed collector lines was studied and verified. The research results show that, compared with the random forest algorithm, decision tree algorithm, CNN, and LSTM neural network, the proposed method significantly improved the location accuracy and is more suitable for the fault distance measurement requirements of collector lines in the complex environments of wind farms. The research conclusions provide technical support and a reference for the actual operation and maintenance of wind farms.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-07-14
DOI
https://doi.org/10.3390/en18143703
Citations
2
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
2.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Method Based on CNN–BiLSTM–Attention for Wind Farm Line Fault Distance Prediction

Ming Zhang, Guangkai Zhou, Qingzhong Gao, Baoliang Liu et al.
2 citations
Energies
Power Systems Fault Detection
2.43
article

A Method Based on CNN–BiLSTM–Attention for Wind Farm Line Fault Distance Prediction

Ming Zhang, Guangkai Zhou, Qingzhong Gao, Baoliang Liu, Chen Zhang
article en
2 citations

Abstract

In view of the complex operating environments of wind farms and the characteristics of multi-branch mixed collector lines, in order to improve the accuracy of single-phase grounding fault location, the convolutional neural network (CNN), bidirectional long short-term memory network (BiLSTM), and attention mechanism (attention) were combined to construct a single-phase grounding fault location strategy for the CNN–BiLSTM–attention hybrid model. Using a zero-sequence current as the fault information identification method, through the deep fusion of the CNN–BiLSTM–attention hybrid model, the single-phase grounding faults in the collector lines of the wind farm can be located. The simulation modeling was carried out using the MATLAB R2022b software, and the effectiveness of the hybrid model in the single-phase grounding fault location of multi-branch mixed collector lines was studied and verified. The research results show that, compared with the random forest algorithm, decision tree algorithm, CNN, and LSTM neural network, the proposed method significantly improved the location accuracy and is more suitable for the fault distance measurement requirements of collector lines in the complex environments of wind farms. The research conclusions provide technical support and a reference for the actual operation and maintenance of wind farms.

EnergiesVol. 18(14)
Shenyang Institute of Engineering (CN)
Openalex Percentile: Top 11%
Power Systems Fault Detection
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Method Based on CNN–BiLSTM–Attention for Wind Farm Line Fault Distance Prediction — Ming Zhang, Guangkai Zhou, et al. · Energies (2025) | TGRS Research Map | TGRS