The Implementation and Application of a Saudi Voxel-Based Anthropomorphic Phantom in OpenMC for Radiological Imaging and Dosimetry

<b>Objectives</b>: This study aimed to implement a high-resolution Saudi voxel-based anthropomorphic phantom in the OpenMC Monte Carlo (MC) simulation framework. The objective was to evaluate its applicability in radiological simulations, including radiographic imaging and effective dose calculations, tailored to the Saudi population. <b>Methods</b>: A voxel phantom comprising 30 segmented organs/tissues and over 32 million voxels were constructed from full-body computed tomography data and integrated into OpenMC. The implementation involved detailed voxel mapping, material definition using ICRP/ICRU-116 recommendations, and lattice geometry construction. The simulations included X-ray radiography projections using mesh tallies and anterior-posterior effective dose calculations across 20 photon energies (10 keV-1 MeV). The absorbed dose was calculated using OpenMC's heating tally and converted to an effective dose using tissue weighting factors. <b>Results</b>: The phantom was successfully modeled and visualized in OpenMC, demonstrating accurate anatomical representation. Radiographic projections showed optimal contrast at 70 keV. The effective dose values for 29 organs were calculated and compared with MCNPX, the ICRP-116 reference phantom, and XGBoost-based machine learning (ML) predictions. OpenMC results showed good agreement, with maximum deviations of -35.5% against ICRP-116 at 10 keV. Root mean square error (RMSE) comparisons confirmed reasonable alignment, with OpenMC displaying higher RMSEs relative to other methods due to expanded organ modeling and material definitions. <b>Conclusions</b>: The integration of the Saudi voxel phantom into OpenMC demonstrates its utility for high-resolution dosimetry and radiographic simulations. OpenMC's Python (version 3.10.14) interface and open-source nature make it a promising tool for radiological research. Future work will focus on combining MC and ML approaches for enhanced predictive dosimetry.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-07-12
DOI
https://doi.org/10.3390/diagnostics15141764
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Implementation and Application of a Saudi Voxel-Based Anthropomorphic Phantom in OpenMC for Radiological Imaging and Dosimetry

Ali Alghamdi
Diagnostics
Advanced X-ray and CT Imaging
article

The Implementation and Application of a Saudi Voxel-Based Anthropomorphic Phantom in OpenMC for Radiological Imaging and Dosimetry

Ali Alghamdi
article en

Abstract

<b>Objectives</b>: This study aimed to implement a high-resolution Saudi voxel-based anthropomorphic phantom in the OpenMC Monte Carlo (MC) simulation framework. The objective was to evaluate its applicability in radiological simulations, including radiographic imaging and effective dose calculations, tailored to the Saudi population. <b>Methods</b>: A voxel phantom comprising 30 segmented organs/tissues and over 32 million voxels were constructed from full-body computed tomography data and integrated into OpenMC. The implementation involved detailed voxel mapping, material definition using ICRP/ICRU-116 recommendations, and lattice geometry construction. The simulations included X-ray radiography projections using mesh tallies and anterior-posterior effective dose calculations across 20 photon energies (10 keV-1 MeV). The absorbed dose was calculated using OpenMC's heating tally and converted to an effective dose using tissue weighting factors. <b>Results</b>: The phantom was successfully modeled and visualized in OpenMC, demonstrating accurate anatomical representation. Radiographic projections showed optimal contrast at 70 keV. The effective dose values for 29 organs were calculated and compared with MCNPX, the ICRP-116 reference phantom, and XGBoost-based machine learning (ML) predictions. OpenMC results showed good agreement, with maximum deviations of -35.5% against ICRP-116 at 10 keV. Root mean square error (RMSE) comparisons confirmed reasonable alignment, with OpenMC displaying higher RMSEs relative to other methods due to expanded organ modeling and material definitions. <b>Conclusions</b>: The integration of the Saudi voxel phantom into OpenMC demonstrates its utility for high-resolution dosimetry and radiographic simulations. OpenMC's Python (version 3.10.14) interface and open-source nature make it a promising tool for radiological research. Future work will focus on combining MC and ML approaches for enhanced predictive dosimetry.

DiagnosticsVol. 15(14)
Imam Abdulrahman Bin Faisal University (SA)
Openalex Percentile: Top 84%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Implementation and Application of a Saudi Voxel-Based Anthropomorphic Phantom in OpenMC for Radiological Imaging and Dosimetry — Ali Alghamdi · Diagnostics (2025) | TGRS Research Map | TGRS